Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты



Предыдущие результаты

 AssetCentre ochen dorogoy product, zato sdelaet to chto nado. CPR9 namnogo legche v ustanovke po sravneniyu s CPR7. Zhelayu udschi v podderzhke etogo producta. Osnovnoj centr po podderzhke v USA, ostalnie centri ne znayut nichego. I esli dazhe chto nibud nesuschestvennoe, oni otpravlyaut case v USA. Poka Udachi

 Руководство пишет вот что: [quote:7634072c6a]Error Codes Generated by the ENI This table shows the error codes that may be generated by the ENI. A full listing of error codes that may be generated by the Message Instruction is shown below. Target node cannot respond because of incorrect command parameters or unsupported command. Possible causes: · The data size of the message is invalid. · The data format is incorrect for any of the supported PCCC messages. · Register parameters are not formatted correctly, or there is not enough data provided. · RS-232 configuration packet data is not the correct size. · The Node Address is invalid or out-of-range. · The distant ENI, controller, or device may not be responding. · There may be a break in the connection between the ENI devices or controllers. · BOOTP/DF1 parameter is invalid[/quote:7634072c6a] Проверили все причины?

 Reference: Technical Note 41204 was released to the Rockwell Automation Knowledgebase which describes a separate issue that involves a similar set of modules as this PSA. The date range of the Technical Note extends outside of the date range of this PSA, Sept 2006 through June 2007. We recommend you review the Technical Note in addition to this PSA. - Issue Description - With the above-mentioned ControlLogix and CompactLogix products, hereafter referred to as Logix products, the following functional issue exists: Functional Issue – A functional issue has been identified with a component used on the above-listed products manufactured from October 2006 through March 2007. A root-cause analysis performed on the component indicates that approximately 1.0% of the products may be affected. Depending on the type of product, the issue may result in erroneous data. Anomalies observed to date have resulted in modules performing a safe shutdown due to internal diagnostics. To date, we have not seen any instances of erroneous data in the field as a result of this issue. Изготовленное в данный период оборудование может быть бракованным. Кто поставил контроллеры из этой партии на взрывоопасные объекты - начинайте закупать валидол.

 [quote:0059423b6f="stAntonio"]Извините, Кемпо, а можно пример? что то я туго сегодня соображаю.[/quote:0059423b6f] Стучись 462144904 - скину тебе скриншоты и объясню что и как Стучись смело даже если меня нет в сети - я просто в инвизе ;)

 [quote="stAntonio"]И вообще возможно ли обращаться к тегам, и их элемента по адресам как это происходит в обычном программировании? В ControlLogix 5550 распределение памяти - динамическое. Поэтому программист имеет доступ не к фиксированому адресу памяти , а к единице хранения данных - тэгу.

 [quote:49268df80f="Dvoeglazov"]Видит. Отформатируйте на FAT16. Но производитель гарантирует работоспособность только со своими Flash (вам уже писали). Решать и рисковать вам.[/quote:49268df80f] PV+ видит 16 GB с FAT32, то что видит я раньше знал, а про FAT32 только что глянул. :) Для Standard PV, я бы предпочел 2711-NM232. Будет дороже, но надежнее.

 Пожалуйста, это минимальные требования: [quote:4461b35816]FactoryTalk Historian System Requirements Server * 3.4 GHz Intel Pentium© Processor * 1 GB RAM * 100 GB available hard disk space * DVD * SVGA TrueColor monitor with 1 MB of video RAM and 1024x768 resolution * Microsoft Mouse or compatible pointing device * Windows Server 2003, Standard Edition * Microsoft Internet Explorer 6.0, Service Pack 1 * 100 Megabit or faster Ethernet card, network cable; concentrator if using twisted pair wiring; TCP/IP protocol Refer to Hardware specification sheet for specific requirements based on database size. Client * 2 GHz Intel Pentium© Processor * 1 GB RAM * 20 GB available hard disk space * CD-ROM * SVGA TrueColor monitor with 1 MB of video RAM and 1024x768 resolution * Microsoft Mouse or compatible pointing device * Windows Server 2003, Standard Edition, or Windows XP Professional, Service Pack 2 Operating System * Microsoft Internet Explorer 6.0, Service Pack 1 * 100 Megabit or faster Ethernet card, network cable; concentrator if using twisted pair wiring; TCP/IP protocol. * Microsoft Excel 2000 or newer for FactoryTalk Historian DataLink or FactoryTalk Historian System Management Tool (SMT) [/quote:4461b35816] http://www.rockwellautomation.com/rockwellsoftware/data/historian/sysreq.html

 [quote:e61b672d91]если не секрет, в насколько обозримом будущем , планируется следующий релиз!! есть такая инфа?[/quote:e61b672d91] Уважаемый колега, Какие могут быть секреты от Вас в нашей отрасли? Теоретически ваше запрос можно реализовывать хоть сейчас же. Прежде всего хочу уведомить о появлении нового модуля для резервирования 1756-RM (1756-IN092A-EN-P April 2008). Этот модуль занимает всего один слот, и его конфигурация через RSLinx аналогична предшественнику 1757-SRM. Этот модуль предназначен для работы в комплекте с 1756-CN2, 1756-CN2R and 1756- EN2T. Еще хочу заметить, что в каждой из корзин могут находиться по 2 процессора (L61-L63), а L64 может быть только один. Модуль имеет reduced switchover time (up to 10 ms). С другой стороны модуль не будет работать с традиционными CNB(R) and ENBT, и также нельзя строить систему, имея в основной корзине 1756-RM а в резервной 1757-SRM или наоборот. С Hardware все на этом. С Software проще, тот же Logix5000 и Linx. [quote:e61b672d91]Придётся подождать до следующего релиза firmware, когда эти модули туда пропишут. [/quote:e61b672d91] Теперь о Firmware. Только только появился redundancy bundle 16.50 и сразу же за ним было обьявленно еще о 2х (16.53 для Standard Redundancy System and 16.53 for Enhanced Redundancy System). Смотрим 1756-RN628G-EN-E and 1756-RN650A-EN-E. You will see two firmware bundles on the RA support site within two weeks (I hope so :) ). For Enhanced Redundancy System please use file with name: V16.53EnhClxRed. Вот и с теоретической частью покончено. А по практической, я не знаю когда это добро появится в Мариуполе, вам виднее. Так что вот так. Дерзайте. Спасибо за внимание.

 Доброе утро, коллеги. Возник вот такой вопрос есть ли возможность командой закрыть клиента RSVeiwSE (приложение stand-alone)? Раньше в RSView32 была команда ProjectStop и можно было остановить и закрыть приложение, а с SE какие есть варианты?

 Understand Спасибо за исчерпывающий ответ!



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
version Rockwell ProSoft Modbus Automation ControlLogix MVI56-MCM Allen-Bradley Logix Windows FactoryTalk PanelView VersaView ControlTower GuardLogix Compact Software Studio Designer 100-E 100-D SMC-50 Energy Saver 1756-RMS-SC Spectrum Encompass Level Ethernet Redundancy Stratix

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.131 секунды