 [color=blue:76382ce10c]Еще RSLinx имеет "DDE/OPC predefined items", некоторые из них: - @Mode returns the current mode of the processor as a string (Run, Program, Remote Run, or Remote Program). - @Status returns the current status of the processor as a string (Ok or Faulted). - @StatusNumber returns the current status of the processor as a number. - @IsPresent allows you to check if your ControlLogix processor is available prior to performing reads or writes. [/color:76382ce10c] А можно поподробней насчет механизма использования этих item-ов из RSView32? Никогда этого не использовал, а штука может быть полезной в случае ее реальной возможности применения. С уважением, Vitaliy D. Burtsev

 [quote:99c51288ed]А в RSView если связи нету то вид объектов не изменяется...[/quote:99c51288ed] Верно только для случая, когда к этому объекту не привязан тег устройства. [quote:99c51288ed]Для диагностики можно, например, назначить какие-нибудь действия (Event), основываясь на бите коммуникаций system\ComErrorValue1 или system\ComErrorValueOPC [/quote:99c51288ed] Не удачный совет, контроллеров может быть более одного... В RSView32 есть замечательная функция - "comm_err(TagName)". Еще RSLinx имеет "DDE/OPC predefined items", некоторые из них: [list:99c51288ed] - @Mode returns the current mode of the processor as a string (Run, Program, Remote Run, or Remote Program). - @Status returns the current status of the processor as a string (Ok or Faulted). - @StatusNumber returns the current status of the processor as a number. - @IsPresent allows you to check if your ControlLogix processor is available prior to performing reads or writes. [/list:u:99c51288ed]

 Для контроля связи можно использовать следующие штатные средства RSView: [quote:8971ebbe40][b:8971ebbe40]Monitoring communications[/b:8971ebbe40] Use any of the following methods to monitor communications: - Activities—In the Activity Log Setup editor, ensure communication errors, warnings, and remarks are enabled and are set up to log to the log file and activity bar. At runtime, information appears in the log file and activity bar, indicating any problems. - Communication status—Ensure communication status is turned on, otherwise communication errors will not be logged to the activity log file or activity bar (even if they have been configured to do so in the Activity Log Setup editor). By default, communication status is turned off until you run the project. To turn communication status on, use the [b:8971ebbe40]ComStatusOn[/b:8971ebbe40] command. - Tag monitor—Use the tag monitor to check the communication status for a device tag. The states are: - Disabled if the node has been disabled in the Node editor or disabled using the NodeDisable command - Error if RSView32 has tried to acquire a value but could not because of some kind of communication error, such as a node not being available or a DDE server not running - Stale if the tag value has been acquired before but does not have an updated value - Uninitialized if the value has never been acquired - Valid if RSView32 has a valid value for the tag - None if there is a problem with the tag definition such as it is not a valid tag type or if the tag database has been accessed with a third–party tool such as Microsoft® Access. If the underlying tag type is valid, editing and saving the tag and then redisplaying the tag monitor will fix the problem. System\com tags—Use the system\com tags to receive a more detailed error message. If the tag monitor reports an error, move to an empty cell in the tag monitor, type system\com* and, when the dialog box appears, click Select All. For a complete list of system\com tags, see Appendix B, System tags. [/quote:8971ebbe40] Для диагностики можно, например, назначить какие-нибудь действия (Event), основываясь на бите коммуникаций system\ComErrorValue1 или system\ComErrorValueOPC и т.п. . [quote:8971ebbe40] Вот в WinCC при отсутствие связи все анимированые объкты заштриховываются (нет связи). А в RSView если связи нету то вид объектов не изменяется, как решить такую проблему?[/quote:8971ebbe40] В RSView Вам предоставляется возможность не просто заштриховать объект, а решить самостоятельно, что с ним делать, и вообще делать ли что-нибудь. Вы можете "надеть" на объект анимацию мигания или изменения цвета, или изменения штриховки на осовании выражения, которое Вы описываете в поле Expression. Хотите заштриховать - штрихуйте по тому или иному биту, нет проблем. А в WinCC Вы имеете такую же свободу действий?

 Добрый день! Вы правы, DIMIOKS. В каталоге нет термометров сопротивления и термопар, но их выпускают довольно много других фирм. Для подключения к модулю 1769-IR могу Вам порекомендовать термометры сопротивления фирмы YOKOGAWA: http://www.yokogawa.ru/measurementtemperature/?prod=211 Технические характеристики данных термометров сопротивления можно скачать здесь: http://www.yokogawa.ru/default.aspx?mode=binary&id=281 Подключение и конфигурирование модулей 1769-IR6 и 1769-OF8C описано в руководствах по подключению: http://literature.rockwellautomation.com/idc/groups/literature/documents/in/1769-in027_-en-p.pdf http://literature.rockwellautomation.com/idc/groups/literature/documents/in/1769-in065_-en-p.pdf Можно воспользоваться и руководствами пользователя данных модулей: http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1769-um005_-en-p.pdf http://literature.rockwellautomation.com/idc/groups/literature/documents/um/1769-um002_-en-p.pdf

 Проблемы нет никакой. Сохраните программу из контроллера на карточке, вставьте карточку в компьютер, она распознается, как диск. Следайте имедж с этого диска и пошлите коллеге мэйлом. Он запишет имедж карточки на свою такую же карточку и вставит в контроллер. Потом нужно загрузить программу с карточки, и если контроллер идентичен, всё будет работать. Вот, почитайте: [quote:48dd3b71ba][b:48dd3b71ba]G153127944: What happens to the application program in a L3x CompactLogix controller when it is powered down and up[/b:48dd3b71ba] When a CompactLogix controller is powered down, that is the power supply is powered down, the power supply sends a signal to the controller that power is going away. When the controllers gets this it will then save the program to battery back ram. When this is done the saved image is marked as valid. Then when the controller is powered back up it checks if anything is loaded in battery backed ram. If there is and it is marked as valid it is loaded in to memory. Then the battery back ram image is marked invalid. The marking of the image as invalid, after loading it, prevents the case of being able to load the wrong image into the controller, if for example, a new user program was loaded into the controller. Events that can cause the controller image to not be saved: 1. The CompactLogix power supply seeing an overvoltage condition. The power supply at this point does not go thru a normal shut down. 2. Unlocking the locking tab on any module between the controller and power supply. 3. Dead battery. 4. Disconnecting the battery after powering down. The image will be saved but lost. In the first 2 cases no image will be saved to battery backed ram. When the controller is powered back up the image saved in battery back ran is marked invalid and will not be loaded. So the controller will power up and appear to have lost its program. In case 3 the controller will save the image to battery back ram. Then the image will be retained for about 30 to 60 seconds. There are capacitors on the controller that will hold up the battery backed ram for 30 to 60 seconds. After the 30 to 60 seconds the controller will powerup and no program will be loaded. Important facts to know: 1. On a power down, the controller memory is saved to battery backed ram whether or not CompactFlash is installed. 2. [b:48dd3b71ba]If CompactFlash is installed and set to load "always", CompactFlash will win over battery backed ram.[/b:48dd3b71ba] 3. [b:48dd3b71ba]If the CompactFlash is installed and set to load "on corrupt", memory will be loaded from battery backed ram unless battery backed ram is corrupt.[/b:48dd3b71ba] 4. Disconnecting the battery after power is removed for 30 to 60 seconds will clear battery backed ram. 5. On power up once the program is restored from battery backed ram , the battery backed ram is marked invalid so that the image will not be re-loaded without a new power down save.[/quote:48dd3b71ba] Вот ещё небезинтересно почитать: [quote:48dd3b71ba][b:48dd3b71ba]G149027134 - Using a 1784-CF64 Card with Logix Controllers to Load Applications and Firmware[/b:48dd3b71ba] Summary of Technote Information: Starting at V12 the 1784-CF64 card would also store the firmware required for the application/project stored on the CompactFlash card. A common question is when will the firmware be updated and how should I configure the card for this to happen. A common request from customers is that they want to use the 1784-CF card to: 1. Reload the application/project to the controller if memory is lost. 2. Update the controllers firmware and load the application/project to the controller if it must be replaced. 3. Do not restore the application/project after a power cycle. The next question is how do I setup the Non-volatile storage feature to do all of these. Should the Load Image be selected as: 1. On Power Up 2. On Corrupt Memory Before we discuss this we should explain the process the controller goes thru. The controller determines what the restore options are. If the controller determines that a restore of the user program is called for it checks that the FW rev is correct. If it is not the controller will update the firmware and then reset itself. The controller will then check again what the restore options are. If the controller determines a restore of the user program is called for it checks that the firmware rev is correct. (This time it is.). Then we restore the user program. So for the above request you would want to select Load Image On Corrupt Memory. L6X controller at V13 (this applies to all controllers that use CompactFlash). Downloaded a program to it and created 2 CF cards. One set to load on powerup (1) and one set to load on corrupt memory (2). 1. Took another controller and loaded FW 15.4. No program loaded, no battery. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 2. Took another controller and loaded FW 12.XX. No program loaded, no battery. Took card 2 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 3. Took another controller and loaded FW 15.4 with the V15 version program loaded, battery. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 4. Took another controller and loaded FW 15.4 with the V15 version program loaded, battery. Took card 2 and inserted it into the controller. The controller stayed at V15 with the V15 program loaded. Nothing was loaded because the memory of the controller was not corrupt. 5. Took another controller loaded with factory default firmware. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 6. Took another controller loaded with factory default firmware. Took card 2 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. [/quote:48dd3b71ba]

 "...Але коли ви читаєте охоче німецьку сторону, потім є одними іншими і schöne Предмет..." http://translate.meta.ua/default.asp :wink:

 Получить общую информацию о RSBizWare можно здесь: [url]http://literature.rockwellautomation.com/idc/groups/literature/documents/br/bizwar-br001_-en-p.pdf[/url] или можно зайти непосредственно на сайт продукта [url]www.rsbizware.com[/url] По генерации отчётов можно посмотреть продукт Microsoft Reporting Services Add-On к MS SQL Server, который явл. компонентом MS Visiual Studio .NET: [url]http://www.microsoft.com/sql/technologies/reporting/default.mspx[/url]

 [quote:0199e92271]Но работает как-то не очень надежно (через 1-2 дня перестают пересылаться значения - проект в 17.000 тегов, наверно много =) ).[/quote:0199e92271] А не пробовали Watcom кэш увеличить? Там не менее 8192 должно быть. Проверьте в HKEY_USERS\.DEFAULT\Software\ODBC\ODBC.INI\Имя_Проекта\Start, вдруг поможет.

 В RSView32 имеется встроеннный мониторинг состояния коммуникаций, поэтому, я думаю, что эту проблему можно было бы решить достаточно просто, без "самодельного" механизма проверки. Можно использовать штатные средства RSView, которые для этого и предназначены. Смотрите, что пишут в руководстве: [quote:984478dd4f][b:984478dd4f]Monitoring communications[/b:984478dd4f] Use any of the following methods to monitor communications: - Activities—In the Activity Log Setup editor, ensure communication errors, warnings, and remarks are enabled and are set up to log to the log file and activity bar. At runtime, information appears in the log file and activity bar, indicating any problems. - Communication status—Ensure communication status is turned on, otherwise communication errors will not be logged to the activity log file or activity bar (even if they have been configured to do so in the Activity Log Setup editor). By default, communication status is turned off until you run the project. To turn communication status on, use the [b:984478dd4f]ComStatusOn[/b:984478dd4f] command. - Tag monitor—Use the tag monitor to check the communication status for a device tag. The states are: - Disabled if the node has been disabled in the Node editor or disabled using the NodeDisable command - Error if RSView32 has tried to acquire a value but could not because of some kind of communication error, such as a node not being available or a DDE server not running - Stale if the tag value has been acquired before but does not have an updated value - Uninitialized if the value has never been acquired - Valid if RSView32 has a valid value for the tag - None if there is a problem with the tag definition such as it is not a valid tag type or if the tag database has been accessed with a third–party tool such as Microsoft® Access. If the underlying tag type is valid, editing and saving the tag and then redisplaying the tag monitor will fix the problem. System\com tags—Use the system\com tags to receive a more detailed error message. If the tag monitor reports an error, move to an empty cell in the tag monitor, type system\com* and, when the dialog box appears, click Select All. For a complete list of system\com tags, see Appendix B, System tags. [/quote:984478dd4f] Для диагностики можно использовать, скажем, системный тэг system\ComErrorValue1 или system\ComErrorValueOPC и т.п. В дальнейшем можно назначить какие-нибудь действия, основываясь на бите аварии коммуникаций. RSView всё равно сканирует Ваши тэги, поэтому ошибка коммуникации будет неминуемо обнаружена, и, возможно, даже скорее, чем при используемом у Вас механизме. Мне ничего неизвестно о существовании возможности исключить какие-нибудь отдельно взятые команды из записи в ActivityLog. Но если уж обязательно необходимо записывать все эти команды, то я мог бы себе представить программу пост-обработки файлов активности, скажем, на VBA, чтобы выбросить из этих файлов всё лишнее.

 Добрый день! [quote:562f391631]1. Soft обновил: RSLinx v 2.43.01 RSLogix500 v7.00 2. Добыл ноутбук со встроеным СОМ1 (чтобы исключить USB-COM) 3. Выяснил, что когда нажимаешь на Auto-Configure (в RSLinx) и если кобель вообще не подключен к SLC, то в окошке видно как перебирается скорость, четность и т.д.. [/quote:562f391631] Это правильно, Linx ведёт себя нормально. [quote:562f391631]Но как только кабель подстыковываешь к SLC - в окошке (рядом с кнопкой Auto-Configure) информация становится по-скуднее: в начале проверка алгоритма CRC, а потом BCC (т.о. одна строка, потом другая). Ну потом неутешительный вердикт :"Check cable..." [/quote:562f391631] Это означает с высокой вероятностью, что неисправен либо кабель, либо порт. Нельзя ли попробовать тот же кабель с другим процессором или тотже процессор с другим кабелем? [quote:562f391631]Может имеется возможность сконфигурировать SLC так, чтобы нельзя было скачать программу через RS232 (как-то этот порт отключить?!)[/quote:562f391631] В принципе, даже если предположить, что каким-то образом изменились установки порта так, что программу загрузить нельзя, то есть процедура, позволяющая сбросить все установки процессора в заводские по умолчанию: [url=http://domino.automation.rockwell.com/applications/kb/RAKB.nsf/6ead4531e08f2074852569bb007630d5/f136ded23c7f35cd85256afb00620f9e?OpenDocument]A14307 - Restoring Factory Defaults to SLC-500 Processors[/url]



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
Error RSLogix ControlLogix sound FTView Control Logix MVI56-104S 1734-AENTR Altivar Add-on Instruction MVI46MCM Ethernet PLC-5 SLC-500 1757-SRM Firmware ComactLogixL32E 1756-L75 1756-RM2 Controlnet cable Promass Client Memory 1769-L32E execution minutes seconds Windows Build 00000d5c Unspecified terminate geehrter automatisch keine globalen F

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.170 секунды