Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты



Предыдущие результаты

 Доброго времени суток. Помогите решить проблему с установкой EDS-файлов. Установлен RSLogix 5000 V17.01.00(CPR 9 SR 1) и RSLinx Classic 2.50.00.20 (CPR 7). В проекте имется контроллер 1769-L36ERM и модуль 1769-IF16C, но их нет в I/O Configuration. Скачал EDS-файлы и с помощью EDS Hardware Installation Tool попытался их установить. Установка 1769-IF16C прошла, но он не появился в окне Select Module, а при установке 1769-L36ERM EDS Hardware Installation Tool выдал ошибки: 1. The following error occurred in the [Params] section of the EDS file: In the 'Param7' entry, the 'Default' field value is out range. 2. The following error occurred in the [Params] section of the EDS file: In the 'Param8' entry, the 'Default' field value is out range. Хотел попробовать установить с помощью RSLogix 5000 module profiles setup, но не смог найти эту утилиту. Подскажите может что то делаю не так?

 [quote:6688561cc9="anforcer"]Если панель простая PV600, то приложения делаются не на FT ME, а на PanelBuilder 3.86. Если же панель PV600 Plus, то делать приложение нужно на FT ME (Machine Edition). FT SE (Station Edition) для полноценных станций операторов, грубо говоря ПК.[/quote:6688561cc9] FT SE включает в себя FT ME (Machine Edition) и, кроме того, FT SE означает [url=https://www.rockwellautomation.com/rockwellsoftware/performance/view/viewse.html]FactoryTalk View® [u:6688561cc9]Site Edition[/u:6688561cc9] (SE)[/url] Для разработки приложений требуется FactoryTalk View [b:6688561cc9][u:6688561cc9]Studio[/u:6688561cc9][/b:6688561cc9] SE или, если речь только о панелях оператора типа PV+, то ME.

 Если панель простая PV600, то приложения делаются не на FT ME, а на PanelBuilder 3.86. Если же панель PV600 Plus, то делать приложение нужно на FT ME (Machine Edition). FT SE (Station Edition) для полноценных станций операторов, грубо говоря ПК. А вообще лучше Вам выбрать SE(локал), поставить станции на каждый станок "буровой", сетевую версию ставить не вижу смысла. Для сбора данных думаю 20-ти OPC будет достаточно! Можно отдельно поставить компьютер - сервер для хранения архивных перьев. Большой плюс SE - есть возможность выбора объема памяти, у панелей с этим сложновато да и с ОПС вы пролетите! По поводу записи данных и хранения поищите в мануалах FT, там про то как настроить сервера все четко написано и про аларм логи тоже, думаю они Вам пригодятся.[/url]

 [quote:c78bba00da="keeper321"]Вы не могли бы дать совет по выбору программного обеспечения для конкретной задачи:[/quote:c78bba00da]Стоит почитать [url=http://www.vdt-solutions.de/modules.php?name=Docs-RA]документацию[/url]. [quote:c78bba00da="keeper321"]как уже говорил, необходимо иметь возможность отображать данные в приложении на экране монитора и на панели (в разных конфигурациях это панели разных типов) т.е. разные станки не подключены в одну сеть т.к. находятся в разных местах ControlLogix+PV600+комп(по ethernet) ControlLogix+PV1000+комп(по ethernet) ControlLogix+PV600 plus+комп(по ethernet) и т.д.[/quote:c78bba00da]Каждому станку по терминалу оператора, т.е. PanelView+, среда ME. PanelView и PanelView Plus - разные терминалы. Компьютер один для всех станков, среда SE. SE в свою очередь бывает двух типов: Station (неразделимые сервер и клиент) и Netwоrk (много серверов, много клиентов). См. [url=http://www.rockwellautomation.com/rockwellsoftware/performance/view/overview.page]здесь.[/url] [quote:c78bba00da="keeper321"]Также необходимо иметь возможно архивирования данных на комп с последующим просмотром архивов и созданием трендов их архива...[/quote:c78bba00da]Можно. [quote:c78bba00da="keeper321"]Что-то слышал про DataLogModels, может ли это приложение работать с несколькими OPC серверами(есть ещё второстепенные данные на ModBus OPC)[/quote:c78bba00da]Не стоит путать понятия [b:c78bba00da]откуда[/b:c78bba00da] (OPC) и [b:c78bba00da]куда[/b:c78bba00da] (DataLog). DataLogModels - модели протоколирования, активных ME - 1 шт, SE - 20 шт. мах. Для ControlLogix лучше [b:c78bba00da]RSLinx Enterprise[/b:c78bba00da]. К другой технике OPC, мы использовали [b:c78bba00da]KepServer Enterprise[/b:c78bba00da] (OPC сервер, но только для Factory Talk View, для ME ранее был в комплекте).

 [quote:6d2b0da62a] 47884 - PowerFlex 40P/70: Fault F111 Hardware Enable Jumper Fault Access Level: Everyone Date Created: 01/04/2008 08:41 AM Last Updated: 12/16/2013 09:50 PM Question Why does my PowerFlex 70 Enhanced Drive fault with a F111? Why does my PowerFlex 40P Drive fault with F111? Environment 22D PowerFlex 40P 22A PowerFlex 70 Answer On PowerFlex 70 Enhanced Drives with the Drive Safe Off option, and the PowerFlex 40P the hardware enable jumper must be removed. If the Hardware Enable Jumper is not removed and the Drive is started, the Drive will fault with F111. This fault description is not covered in the trouble shooting section of the current drive user manual. Removing the Enable jumper to the left of the Safe Off Option board and above the I.O. connection board will correct the fault Note - when mentioning the hardware enable jumper, ensure the customer is not confusing the drives hardware enable jumper with any links on the safety modules. As the drives hardware enable jumper is quite small some customers do not see it. On the PowerFlex 40P, if 24V DC is applied to terminals 3 and 4 of the Safe-Off, but 24V DC is not applied to terminal 1 on the drive and a start command is given the drive will issue a F111 fault.[/quote:6d2b0da62a]

 [quote:d4cb8ea0f8="anforcer"]Проще получилось - у заграничных наших друзей подсмотрел, создается дисплей скрытый или можно использовать существующий, но постоянно открытый, добавляется поле [b:d4cb8ea0f8]input[/b:d4cb8ea0f8], привязывается тег системного времени (минутный, секундный, часовой, суточный, годовой), а на изменение change в VBA привязали нужный код и вуаля работает![/quote:d4cb8ea0f8]Необязательно поле [b:d4cb8ea0f8]input[/b:d4cb8ea0f8], можно отображение. [quote:d4cb8ea0f8="anforcer"]Есть небольшие секундные задержки но это не страшно![/quote:d4cb8ea0f8]В SE Network задержки будут больше, чем для Station. Еще в SE Network можешь иметь проблему, т.к.:[quote:d4cb8ea0f8="anforcer"]...для чтения и [color=red:d4cb8ea0f8][b:d4cb8ea0f8]записи тегов[/b:d4cb8ea0f8][/color:d4cb8ea0f8]. [/quote:d4cb8ea0f8] Код VBA принадлежит клиенту: сколько клиентов - столько записей.

 Вообщем приобрели данный продукт (версия 7.0), по-моему даже в вдт автоматизация, но вот не задача- ключ с диском придет после НГ, есть ли у кого образ диска дистрибутива, пока хоть так поработаем в ограниченном режиме?

 300 не хватит. промежуточных версий нет. это что-то меняет? FactoryTalk View SE Station 15 Display - €1.320,00 RSView32 Runtime 300 - €2.140,00

 [quote:417d95c522="Ryzhij62"]Ну и зачем Вам тогда FTView? Ставьте RSView32, там именно так и делалось, как Вы описали.[/quote:417d95c522] FactoryTalk View SE Station 15 Display - €1.320,00 RSView32 Runtime 1500 - €3.500,00 при этом FTView значительно приятней на ощупь :) [quote:417d95c522="maxim"]Если у вас каждый клиент будет подключен к своему серверу, тогда у вас при неисправности сервера, клиент потеряет данные и не получит их[/quote:417d95c522] да, но! рядом будет стоять второй компьютер, с идентичным, и что самое главное - работающим софтом, которого достаточно для управления процессом пока чинится первый (напоминаю, что лицензия типа Station - это клиент с сервером на одной машине, без возможности подключения к другим серверам)

 Как известно, в ответственных системах рекомендуется установка двух FactoryTalk View SE Server, которые одним щелчком мыши объединяются в резервированную пару. Плюс произвольное количество клиентов. А что, если очень хочется сэкономить? Жизнеспособна ли конфигурация из двух FactoryTalk View SE Station, подключенных к одному контроллеру и одновременно выполняющих одинаковые проекты? Что мы теряем по сравнению с системой из 2 резервированных серверов + 2 клиента? Разница по цене почти в три раза.



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
Automation Fatal Error RSLogix ControlLogix sound FTView Control Logix MVI56-104S 1734-AENTR Altivar Add-on Instruction MVI46MCM Ethernet PLC-5 SLC-500 1757-SRM Firmware ComactLogixL32E 1756-L75 1756-RM2 Controlnet cable Promass Client Memory 1769-L32E execution minutes seconds Windows Build 00000d5c Unspecified terminate geehrter automatisch

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.128 секунды