Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты



Предыдущие результаты

 [quote:d2da7827b8="andy_18"]по какой причине не подходит любая другая батарея ?[/quote:d2da7827b8] Не знаю. Должно работать, как долго - пробуй. Ищи на подобные характеристики (в магазинах этого не знают): [code:1:d2da7827b8]PANASONIC Type CR-17335E Electrical Characteristics at 20oC (68oF): 3V nominal voltage, 1750mAh nominal capacity @ 1.0mA standard drain and cut-off voltage down to 2.5V @ 20oC (68oF). 80mA maximum pulse current.. Load Characteristics (Temp: 20oC (68oF)) Load Approximate time of discharge (3.0V to 2.0V) 5.6kΩ @ 0.5mA 3500 hours 10kΩ @ 0.29mA 6100 hours 20kΩ @ 0.14mA 12200 hours[/code:1:d2da7827b8]Как видно из характеристик - малые токи (возможно и саморазряд мизерный). Очень давно применял для PLC-5 батарею из трех элементов NiCd (1.2 V, 350mAh) - работало, но не долго (саморазряд). Потом это-же для SLC - аналогично. Причем для PLC-5 нужно 3.6V, а для SLC - 3 V.

 Добрый день! Попробуйте почитать документ http://literature.rockwellautomation.com/idc/groups/literature/documents/rn/1756-rn684_-en-p.pdf стр.5 - это возможно Ваш случай. Если есть время - лучше напишите побольше, что делали, как делали, зачем делали и тд. ... больше информации для размышления :о) ... Например зачем Вы со Standart на Enhanced перешли. 16.57 вроде бы и создавали что бы 1756-RM понимала вместо SRM модулей. и еще - http://ab.rockwellautomation.com/Programmable-Controllers/ControlLogix-Redundancy-Modules#/tab5

 Здравствуйте, Ольга! Действительно, RSView32 уже давно сильно устрела. Если не нужен выделенный сервер и клиенты, то посмотрите на FactoryTalk View Site Edition Station: [quote:e637da4eba]FactoryTalk View Site Edition Station allows stand-alone (non-distributed) applications to run on a single computer. Note: Both RSLinx for FactoryTalk View and RSLinx Enterprise are included with FactoryTalk View Site Edition Station. Catalog Number Description 9701-VWSB015AENE FactoryTalk View Site Edition Station 15 Display 9701-VWSB025AENE FactoryTalk View Site Edition Station 25 Display 9701-VWSB100AENE FactoryTalk View Site Edition Station 100 Display 9701-VWSB250AENE FactoryTalk View Site Edition Station 250 Display 9701-VWSB000AENE FactoryTalk View Site Edition Station Unlimited Display[/quote:e637da4eba]

 Dear colleagues, I have a little misunderstanding. There is a 2 wire flowmeter in the field. I connect it to the IS barrier and then to the input module (1756-IF16H). IS barrier is a repeater power supply from Phoenix-Contact. How do you think, do I need a power supply at the module input? Because the flowmeter is powered by IS barirer. Or the power supply in the input of the module is for only module?

 [quote:41967363f0="andy_18"]Можно-ли на панели Panelview 1500 пролистывать алармы постранично, а не по одной строчке. Если да, то как ?[/quote:41967363f0] Можно - необходимо использовать [b:41967363f0]AlarmList[/b:41967363f0]. Штатно имеется экран [ALARM] с [b:41967363f0]AlarmBanner[/b:41967363f0] от него можно уйти. Надеюсь по картинке все понятно. [URL=http://piccy.info/view3/3494394/26ef66610e128e5dcf9bfb10e96eb9b6/orig/][img:41967363f0]http://i.piccy.info/i7/aaddf3bc5746ee8c3d7d3db97c475d68/4-44-1297/17227602/AlarmList_800.jpg[/img:41967363f0][/URL][URL=http://i.piccy.info/a3c/2012-09-21-06-41/i7-3494394/793x538-r][img:41967363f0]http://i.piccy.info/a3/2012-09-21-06-41/i7-3494394/793x538-r/i.gif[/img:41967363f0][/URL] Картинки для PanelView Plus. Для PanelView Standard аналогично.

 [b:d971ff1b4b]Дано:[/b:d971ff1b4b] Win2003 server R2 Standard SP2 RSView32 7.50 FactoryTalk_Activation_3.30.00 [b:d971ff1b4b]Вопрос:[/b:d971ff1b4b] система тихо-мирно работает полгода... и вдруг при перезагрузке сервера выскакивает такое окно (см. картинку) "Factory Talk Activation Daemon Подпись ошибки---------------------------- szAppName: flexsvr.exe ofset: 00103442" [URL=http://www.radikal.ru][img:d971ff1b4b]http://s019.radikal.ru/i619/1208/d4/e592ba82fd95.png[/img:d971ff1b4b][/URL]

 Если кому-то пригодится,вот что ответили в поддержке: [list:f362b0d717] Problem Testing a display with a FactoryTalk Alarm and Events Alarm Summary object results in the following error in the Summary: Insufficient Resources exist on <shortcut name> to support Alarm and Events functionality. Environment Application is trying to subscribe to Analog (ALMA) or Digital (ALMD) alarm Controller running out of memory. Ethernet module peaked at a very high CPU usage when you launch the Ethernet module Web browser. Large number of Subscribers when you open one of the Analog (ALMA) or Digital (ALMD) instruction Properties Status tab. Insufficient disk space. Cause Creating multiple backups of an Application with RSLinx Enterprise enabled for Alarm and Events support. Solution Open FactoryTalk Administration Console expand the Application. Delete the RSLinx Enterprise server or right click on RSLinx Enterprise --> select Properties--> Uncheck Enable alarm and events support for older applications. Note: Each RSLinx Enterprise server with Alarm and Events enabled will consume 100k of Controller memory for buffering. 49886 - SE 5.0 Alarm and Events Error: "Unable to subscribe to alarms from the controller plc insufficient memory to create subscription" Access Level: TechConnect Date Created: 03/04/2008 09:59 AM Last Updated: 02/19/2011 10:45 AM Neither a new SE project ( distributed or stand alone ), or an existing project ( that may have been working ) works with the Factory Talk Alarm and Events Summary, even though the PLC is triggering alarms successfully. We see the error: " Unable to subscribe to alarms from the controller plc insufficient memory to create subscription ." This error is indicating that there is a memory issue in the Logix processor that is servicing the alarms and that the HMI server is unable to re-register with the alarm server. Please check that there are sufficient resources in the Logix processor to service the HMI server. This can also indicate an issue with licensing the dedicated project's HMI server activation is either being used by another HMI server running in parallel, or it ( example, RSVSERV.XXX ) does not exist on the PC. Check to see that we have enough activations free to attach to the current project and restart. [/list:u:f362b0d717] Всё касается вопросов связанных с ресурсами контроллера и "Alarm and Events".

 Добрый день. Я так понимаю здесь помогают с решением любых вопросов. Проблема в следующем: сделал образ системы с помощью Acronis True Image 2011 с расширением *.TIB. Теперь хочется запустить его через VMWare Workstation 8.0. Для конвертации образа установил VMWare vCenter Converter Standalone 5.0. Далее всё делал по инструкции. Когда выбираю этот образ для конвертации и нажимаю next, появляется сообщение о невозможности выбора этого образа как источника. Хотя в описании конвертера написано, что образы Acronis поддерживаются для конвертации. Помогите, пожалуйста, решить мою проблему.

 [quote:42d9f8bf89="Gray_Gray"] Printer Port RS-232 В документации указано, что RS-232 порт только для принтера. [/quote:42d9f8bf89]Пардону просим, но в какой документации Вы сие вычитали? 8O В документе от производителя [url=http://literature.rockwellautomation.com/idc/groups/literature/documents/um/2711-um014_-en-p.pdf]PanelView Standard Operator Terminals[/url] на 43 странице в 17 пункте таблице черным по-английски указано: [quote:42d9f8bf89]RS-232 Printer/File Transfer Port - Connects to a printer. [b:42d9f8bf89]On[/b:42d9f8bf89] remote I/O, [b:42d9f8bf89]DH+[/b:42d9f8bf89], DF1, DeviceNet, EtherNet/IP, or ControlNet [b:42d9f8bf89]terminals, [u:42d9f8bf89]this port also connects to the RS-232 port of a computer for transferring applications[/u:42d9f8bf89].[/b:42d9f8bf89] The RS-232 port on the DH-485 or RS-232 (DH-485) terminal is used to connect a printer but not for file transfers.[/quote:42d9f8bf89] Ваша панель оператора прекрасно соединится с компьютером по RS232-кабелю 2711-NC13 или 2711-NC14, распиновка которого приведена на 200-й странице всё того же документа, с помощью программы PanelBuilder в режиме автоматической конфигурации порта. Надо только убедится, что используемый для связи с панелью COM-порт не занят другой программой, тем же RSLinx, например. А если у Вас есть PMCIA Flash ATA карточка, то выгрузить/загрузить проект и перепрошить панель можно гораздо быстрее. Не сумлевайтесь, таких панелек у меня под надзором около десятка ;) Всё на более современные никак не переползём. Удачи! PS Полная распиновка кабеля [url=http://literature.rockwellautomation.com/idc/groups/literature/documents/in/2711-in037_-en-p.pdf]приведена тут[/url]

 Пожалуйста: http://vdt-automation.de/docs_ru/Drives/Standard_Drives/22comm_e_pp_nl_8_23.pdf http://literature.rockwellautomation.com/idc/groups/literature/documents/um/22comm-um004_-en-p.pdf http://literature.rockwellautomation.com/idc/groups/literature/documents/um/22b-um001_-en-e.pdf http://literature.rockwellautomation.com/idc/groups/literature/documents/qs/22b-qs001_-en-p.pdf http://vdt-automation.de/docs_ru/Drives/Standard_Drives/22b-um001d-ru-e.pdf



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
Fatal Error RSLogix ControlLogix sound FTView Control Logix MVI56-104S 1734-AENTR Altivar Add-on Instruction MVI46MCM Ethernet PLC-5 SLC-500 1757-SRM Firmware ComactLogixL32E 1756-L75 1756-RM2 Controlnet cable Promass Client Memory 1769-L32E execution minutes seconds Windows Build 00000d5c Unspecified terminate geehrter automatisch keine glo

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.151 секунды