 Уважаемые колеги, Намедни мне попалась одна интересная статейка (читайте ниже). Мне кажется, что автор статьи отчасти прав. 8O [b:c99840f97c]Information Overload Pushing Workers to the Brink[/b:c99840f97c] [i:c99840f97c]By David R. Butcher[/i:c99840f97c] People and organizations cannot keep up with the volume of information produced by technological innovation, as information overload is pushing workers closer to theirbreaking point. How much information is too much, and what is it doing to our ability to be productive? Information overload is pushing workers to the brink and cutting into workplace productivity, according to the LexisNexis-commissioned 2008 Workplace Productivity Survey, which polled 650 employees in a variety of industries. According to the survey, a majority of professionals feel they are close to a breaking point, where they will be unable to effectively process or handle any increase in information flow. The survey found 68 percent of professionals wished they could spend less time organizing information and more time using it. Workers admit that not being able to lay their hands on the right information at the right time impedes their ability to work efficiently, as another 85 percent of respondents said not finding the right information at the right time was a significant time waster. Meanwhile, 62 percent said they spent too much time sifting through useless information. “The information age has brought the American professional workforce to an information overload,” Mike Walsh, CEO of LexisNexis U.S. Legal Markets, said in a statement. If we continue to work this way day after day, our brains lose the ability to fully focus our attention and we develop what he has labeled “attention deficit trait,” according to Dr. Edward Hallowell, founder of the Hallowell Center, which provides holistic treatment and education about ADHD for both children and adults, and author of Driven to Distraction. This condition, which seems to be becoming an epidemic, makes us feel perpetually distracted, impatient, disorganized and overwhelmed by our work. Our performance levels on important tasks also drop with “attention deficit trait” because fully focusing our attention is critical to tapping into our brain’s higher functions. Research shows that when people are able to fully focus on one task, their brains automatically screen out distractions and they become more creative and deliver their best performances.

 Вот, посмотрите в Knowledge Base: [b:235d3d6c37]CIP Messaging Reference[/b:235d3d6c37] [b:235d3d6c37]DH+ / RIO[/b:235d3d6c37] DH+ Diagnostics G18529 DHRIO remote rack retry counters G20391 DHRIO DH+ node address A17910 DHRIO DH+ active node table A17854 DHRIO rio status object A17914 Getting and Clearing Diagnostic Counters G96749451 [b:235d3d6c37]ControlNet[/b:235d3d6c37] Flex Module Info G19246 Node Number G19205 CPU Utilization G18809 LED Status G18643 CNB node address Q51228857 Cnet diagnostic and cable redundancy status A18170 Cip messages to 1747SCNR P19786 Resetting PLC5 diags counters on ControlNet A8361507 resetting ControlNet Diagnostic Counters TN ID 41650 [b:235d3d6c37]EtherNet[/b:235d3d6c37] ENET IP Information G18770 ENET diagnostic counters A18389 ENBT Diagnostic Counters Q16739464 ENBT Media Counters Q111833722 ENBT Baud and Duplex Q7753033 ENBT Forcing Baud and Duplex A41930091 ENBT CPU utilization G63659254 ENBT IP Information G82553071 ENBT Host Name Q111838865 [b:235d3d6c37]DeviceNet[/b:235d3d6c37] DNB explicit message example A17630 DNB Explicit message to Panelview example A17520 [b:235d3d6c37]Processor[/b:235d3d6c37] Firmware Level Q29537172 Program Edits A29430452 Program Download Q29427803 Program Name A28555551 Date and Time G20246 Mode Change (Run / Program) G19586 Changes periodic task execution interval A19765 Clear controller faults (major) G20159 Grab controller free memory G19880 Gets controller run/prog mode status A10549732 cpu backplane counters A20360 Increasing the CPU's unconnected buffers A2846512 Obtaining the controller FW level A21366 Changing the serial port from user to system A20455 Lgx unconnected Buffer changes G20181 OK LED status, Keyswitch position Q63938700 Changing the Serial Port Control Line Programmatically A67244256 Obtaining the keyswitch position A86054621 [b:235d3d6c37]I/O Modules[/b:235d3d6c37] 1794VHSC CIP messages. G20558 Flex with LGX, Cnet and no profiles before 11.xx A20248 Resetting diagnostic latch bits A45740757 Resetting electronic fusing A19814 Obtaining Calibration Data (1756-IR6I/IT6I) A67051751 Obtaining Calibration Data (1756-IF16) G51632465 [b:235d3d6c37]SERCOS Modules[/b:235d3d6c37] Current Ring Phase Q62831754

 Описание ситуации: Концевой размыкатель установлен на подвижном защитном ограждении станка, которое предотвращает доступ оператора в опасную зону. В соответствии с требованиями стандарта EN 954 такие компоненты должны иметь уровень безопасности (Safety Integrity Level, SIL) не ниже SIL3. Проблема: Не могу разобраться с маркировкой на этом размыкателе. На шильдике приведена такая информация PIZZATO Italy Ith 10A VDE 0660 IEC 947-5-1 IP 65 AC 15 3A 400 V~ A 600 Q 300 IND CONT EQ usLISTED 58XO K04 FR1-10402 FX 693 Каталог производителя http://www.pizzato.com/PizzatoWeb/UserFiles/File/pdf/ZE_CTL18C05-ENG_4_9-14.pdf Вопрос: Помогите pls разобраться с приведенной на шильдике и в каталоге производителя информацией и с определением уровня SIL.

 [b:b5ed57f383]About the Security Feature[/b:b5ed57f383] The Security feature allows you to control the individual users’ access to RSLogix 5000 projects and controllers. Using RSI Security Server software, you control access to your projects and controllers based on: - the individual user logged into a workstation - the project the user is attempting to access - the workstation from which the user is attempting to access the project Typically, you would use RSI Security Server software to grant or deny permission to perform a particular action on a particular project to a particular person at a particular workstation. Note: The security feature is primarily intended to prevent accidental unauthorized access to your projects and controllers. It is important to note that while the feature does provide some protection against intentional unauthorized access, it is not intended to provide protection against sophisticated system "hackers." You should exercise your own additional precautions against such unwanted access. RSI Security Server grants or denies access based on four pieces of information: - user ID (i.e., the user’s login name) - workstation ID - action name (i.e., the activity the user is trying to perform, such as data table modification, or processor mode change) - resource name (i.e., controller name) In addition, you can group resources, actions, persons, and workstations via access control lists, which define certain characteristics to determine access levels. [b:b5ed57f383] RSLogix 5000 and RSI Security Server[/b:b5ed57f383] When used with RSLogix 5000, RSI Security Server supports 3 global actions and 6 project-related actions. Global actions are not tied to a specific project, and may include: - securing the controller - creating a new project (either through the New Controller dialog, or through the Translator Tool utility) - updating your firmware. The project-related actions allow you to perform specific tasks on a specific project or group of projects, and may include: - viewing a project - going online [color=darkblue:b5ed57f383]- maintaining a project (e.g., saving, converting, exporting, downloading, setting/forcing tag values, etc.)[/color:b5ed57f383] - full access (e.g., editing a project), unsecuring the controller, or updating firmware. Note: Access to these actions is hierarchical. For instance, if you have access to the Go Online action, you also have access to the View Project action; if you have access to the Maintain Project action, you can also access Go Online and View Project; and finally, if you have Full Access, you can access Maintain Project, Go Online, and View Project. Defining your levels of security begins with deciding the type of access you want to allow to each user, project, or workstation. The following tables can help you to identify your security needs.

 Ну так можете его и использовать. Он же для этого и предназначен. [quote:76dcd2bb5f]The Schneider OPC Server is designed [b:76dcd2bb5f]to connect PC-based applications (HMI, SCADA, custom applications, etc.) to industrial devices (PLCs, devices, I/O modules, etc.)[/b:76dcd2bb5f] using multiple communication networks. The OFS package includes: * The OPC server software implementing a gateway between the PLC protocols and OPC; * A tool for configuring the OPC server; * Low level drivers for communication with Modicon Telemecanique PLCs; * A test OPC client allowing to check the communication between the different elements connected * A manager giving access to detailed information about the server. [/quote:76dcd2bb5f] http://itcofe.web.cern.ch/itcofe/Services/OPC/RecommendedTools/Servers/SchneiderOFS/welcome.html Вообще, такой софт выпускает множество фирм, например: http://www.automatedsolutions.com/products/opcmodbus.asp http://www.kepware.com/Spec_Sheets/Modbus_Ethernet.html http://www.opcsystems.com/modbus.htm

 [quote:27c17412a7]Четко и понятно - приятно работать :) [/quote:27c17412a7] Большое спасибо, Слава :) [quote:27c17412a7]Является ли правильным данный подход, или это можно делать как-то автоматически, или можно системными средствами переименовывать узлы, а не вручную? Заранее спасибо! :)[/quote:27c17412a7] Да, в принципе, это правильно. Вообще, это можно сделать средствами VBA в RSView32. [u:27c17412a7][url=http://domino.automation.rockwell.com/applications%5Ckb%5CRAKB.nsf/0/41C6EA9F10CCF48085256B4C004C911F?OpenDocument]A21171 - How to configure RSView32 to switch between two RSLinx Gateways used in a redundant pair[/url][/u:27c17412a7] Вот здесь ещё инфо: [u:27c17412a7][url=http://domino.automation.rockwell.com/applications%5Ckb%5CRAKB.nsf/0/2DD01D53E89359E085256AFB005472B9?OpenDocument]A5054 - Node Level Redundancy - A comparison of the Alias Topic and the NodeSwitch Command[/url][/u:27c17412a7]

 Существует много чего :) Например, хорошие и надёжные датчики Enfdress + Hauser, рекомендую: http://www.uk.endress.com/ (Фирма немецкая, но линк англоязычный, чтоб Вам было легче читать :) ) Там в меню Рroducts выберите Products, Services, Solutions, затем Measurement Products и Level. Тыкайте в линки и читайте инфо, выберите самый подходящий датчик :) Есть ещё Honeywell, Emerson, Kobold.



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
ProSoft Modbus Automation ControlLogix MVI56-MCM Allen-Bradley Logix Windows FactoryTalk PanelView VersaView ControlTower GuardLogix Compact Software Studio Designer 100-E 100-D SMC-50 Energy Saver 1756-RMS-SC Spectrum Encompass Level Ethernet Redundancy Stratix

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.187 секунды