Предыдущие результаты
Обычно это бывает, если драйвер ключа установлен некорректно. Вот, что пишут производители:
[quote:0424bd436d]
[b:0424bd436d]Activation was not successful, no dongles were detected[/b:0424bd436d]
When using the Activation Wizard to get activations for a dongle and you see the error message,
No dongles were detected on this computer. If the dongle is plugged in, you may need to load drivers for the dongle before running this wizard. Click the Back button to try detecting the dongle again, or to change your selections.
It means that the dongle driver was either not installed or improperly installed.
[color=darkblue:0424bd436d][b:0424bd436d]To resolve this issue:[/b:0424bd436d]
In the Add/Remove Programs dialog box, locate the driver install named “HASP Device Drivers”, and remove it. [/color:0424bd436d]
Manually reinstall the drivers by running hdd32.exe. The dongle install programs are in the FactoryTalk Activation Tools directory, which by default is \Program Files\Rockwell Software\FactoryTalk Activation\Tools
[/quote:0424bd436d]
|
[quote:e11f6dc000="oldDad"]
1) HMI Server должен быть создан локально в FactoryTalk View Studio на компьютере с Windows Server 2003.
[/quote:e11f6dc000]
а как это сделать?
Машина на которую ставилось вс это добро:
Windows Server 2003 R2
Standart edition
SP2
|
Проблем может быть несколько:
- несовместимость с каким-либо установленным софтом, например, антивирусом. Известна, например, несовместимость с Norton Internet Security.
- наличие вирусов и/или spyware. Известны случаи, когда вследствие этого нарушался стек WinSock2.
- может быть нарушен порядок установки пакета.
Первое, что бы я сделал - это установил пакет заново на чистой свежей Windows.
Далее, известны случаи, когда FactoryTalk View Studio на Windows XP не может создать удалённый сервер, расположенный на компьютере под Windows Server 2003. если это тот самый случай, то есть два момента:
1) HMI Server должен быть создан локально в FactoryTalk View Studio на компьютере с Windows Server 2003.
2) Можно создать новый HMI Server на мащине с Windows XP, затем сделать backup, затем сделать его restore на компьютере с Windows Server 2003, а затем подключить его к аппликации.
|
Простите, не очень понял: что именно нужно перенести с [i:74a1260319]украденного[/i:74a1260319] ноутбука? :)
В принципе, при FactoryTalk активации вопрос решается следующим образом:
1. Вы сообщаете компании, у которой приобрели программный продукт, его данные регистрации: каталожный номер продукта, его серийный номер, имя и фамилию лица, на которое продукт зарегистрирован.
2. Эта компания инициирует в Rockwell процедуру возобновления активации.
3. Вам сообщают б окончании процедуры.
4. Вы регистрируете продукт заново на новой машине.
|
Вот такой код проверенно работает в VBA Factorytalk View SE:
[code:1:b6d8ebc5a5]Dim TestString As String
TestString= "Shopping List"
aString = Replace(TestString, "o", "i")[/code:1:b6d8ebc5a5]
А в RSview32 попробуйте так:
[code:1:b6d8ebc5a5]Dim MyString
MyString = "The dog jumps" ' Initialize string.
Mid(MyString, 5, 3) = "fox" ' MyString = "The fox jumps".
Mid(MyString, 5) = "cow" ' MyString = "The cow jumps".
Mid(MyString, 5) = "cow jumped over" ' MyString = "The cow jumpe".
Mid(MyString, 5, 3) = "duck" ' MyString = "The duc jumpe".[/code:1:b6d8ebc5a5]
|
Насчёт PanelBuilder - не рекомендую, это ПО давно устарело. Это для старых чёрных PanelView, ещё не PanelView Plus, они не рекомендуются для новых разработок.
А по поводу FactoryTalk View ME - обратитесь, пожалуйста, в ближйший наш офис, Вам постараются помочь.
[url=http://www.rockwellautomation.com/solutions/integratedarchitecture/resources4.html#ftme]Вот здесь фирльмы во Flash по FactoryTalk View ME и по другим продуктам[/url]
|
С панелями вроде все понятно. Но хотелось бы еще посмотреть на инструменты разработки ПО. Скажите, доступны ли Demo-версии PanelBuilder и FactoryTalkME? Может быть дадите ссылочку откуда можно их скачать?
Поиск по ссылкам на сайте, к сожалению ничего не дал.
Заранее спасибо.
|
Здравствуйте!
Нет, панели оператора программируются также с помощью PanelBuilder, FactoryTalkME или вообще без пакета программирования (см. различные семейства панелей).
RSView32 предназначена для программирования "полноценнных" компьютеров", в том числе - промышленных. ВНИМАНИЕ: этот продукт уже устарел.
|
Вопрос как проект с контроллером, созданный в RSLogix 500, используя RSLogix emulate 500 смоделировать с проектом панели, созданной в FactoryTalk View Studio ME5.0? Информация есть по ссылке ниже, но она закрыта ключиком....?
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation.cfg/php/enduser/std_alp.php?p_sid=AUKMCNrj&p_lva=25539&p_li=&p_accessibility=0&p_redirect=&p_page=1&p_cv=&p_pv=&p_prods=0&p_cats=0&p_hidden_prods=&prod_lvl1=0&cat_lvl1=0&p_search_text=rslogix500+emulate+with+ME&p_new_search=1&p_search_type=answers.search_nl
Answer ID 29338
|
[quote:6477bb3e3c]создается впечатление, что ПО RSView32 оставляет желать лучшего…[/quote:6477bb3e3c]
Хотя я и не совсем представляю себе, чего именно оставляет желать RSView32, хотелось бы обратить Ваше внимание на то, что RSView32 - это довольно уже пожилой продукт, который выпускается и с успехом применяется уже более 10 лет (с модификациями, опциями и дополнениями).
Возможно, Вас больше устроил бы такой современный продукт, как FactoryTalkSE (который тоже уже несколько лет выпускается)?
|
Предыдущие результаты
Ещё результаты |
|
| |
|