Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты



Предыдущие результаты

 Это делается с помощью оборудования Prosoft Technology, причем есть разные варианты. Например: [url=http://www.prosoft-technology.com/Products/Gateways/PLX3x/PLX31/EtherNet-IP-to-Siemens-Industrial-Ethernet]PLX31-EIP-SIE[/url] [url=http://www.prosoft-technology.com/Products/Gateways/PLX3x/PLX32/EtherNet-IP-to-Siemens-R-Industrial-Ethernet-Communication-Gateway]PLX32-EIP-SIE[/url] [url=http://www.prosoft-technology.com/Products/Rockwell-Automation-In-chassis/Platform/ControlLogix/Siemens-Industrial-Ethernet-Communication-Module]MVI56E-SIE[/url] [url=http://www.prosoft-technology.com/Products/Rockwell-Automation-In-chassis/Platform/ControlLogix/Message-Manager-for-Industrial-Communication]ILX56-MM[/url]

 Добрый день! Есть ли у кого опыт получение данных из контроллера S7-400 в ControlLogix по Ethernet? Спасибо!

 Eugeny Спасибо, приблизительно так мы и поступили. При общении с тех.поддержкой RA нам подтвердили, что v.8.00 имеет указанную проблемму с алармами, и она будет исправлена, скорее всего, только в следующей версии. Тема закрыта

 И ещё, по инструкции, что Вы мне прислали, скомпилировал проект 5 Screen Demo, на этом же компьютере открываю его, на другом в браузере с установленным и включенным плагином Silverlight, открываю по адресу как в инструкции, в итоге ничего, такого католога не существует в папке inetpuk/wwwroot/ . В чём причина?

 Вылетает ошибка при попытке открыть проект в 8 версии FT View SE Local В чём может быть причина? [img:c814fb92cd]http://i62.tinypic.com/2m3qjv7.png[/img:c814fb92cd][/img]

 Because VBA in the project is single threaded, if you are using any other VBA (such as for navigation or Display_AnimationStart), the above "To play the file WAV more than one time..." will not work. Here is a better way: 1. Create 8 HMI Digital Device Tags (not memory tags) called "SevTrig1" to "SevTrig8". 2. Create 8 HMI String Memory Tags called "SevSound1" to "SevSound8" (retentive) and set initial value to your your wav files including full path (Ex: C:\AlmSound\Sound.wav) 3. In the Alarm Setup / Severities tab: Place "SevTrig#" tags in External Bell for Severity 1 thru 8. 4. Create an HMI Screen (that will be hidden with /ZA). On this screen create 8 rows (1 per severity): Severity 1 = # sssssssssssssssssssssssssssssssssssssss where: * "Severity 1 =" is text with Color Animation using tag "SevTrig1" * "#" is a NumericDisplay named "SeverityInd1" (ExposeToVBA = "VBA Control") with the below expression (step 5) and VBA code (step 6). * "ssss..." is StringDisplay named "SevSndFile1" (ExposeToVBA = "Type Info Extension") with Expression: "SevSound1" Duplicate this line for 2 through 8. 5. In the NumericDisplay Properties / Expression, place the following expression (adjust for 2-7): * SeverityInd1 Expression: IF system\AlarmSummaryItemsUnacked == 0 THEN 0 ELSE IF SevTrig1 AND interval( "5 Sec" ) THEN 1 ELSE 0 * SeverityInd8 Expression: IF system\AlarmSummaryItemsUnacked == 0 THEN 0 ELSE IF SevTrig1 THEN 0 ELSE IF SevTrig2 THEN 0 ELSE IF SevTrig3 THEN 0 ELSE IF SevTrig4 THEN 0 ELSE IF SevTrig5 THEN 0 ELSE IF SevTrig6 THEN 0 ELSE IF SevTrig7 THEN 0 ELSE IF SevTrig8 AND interval( "5 Sec" ) THEN 1 ELSE 0 6. For NumericDisplay "SeverityInd1" thru "SeverityInd8", place the following in VBA: Sub SeverityInd1_Change() On Error Goto Exit_Err If SeverityInd1.Value = 1 Then DisplayClient.Application.ExecuteCommand "PlayWave " & ThisDisplay.SevSndFile1.Value End if Exit_Err: End Sub By following this pattern, the individual playwave above will then fire once every five seconds only for the most important severity active. That will allow other VBA code to run during page changes, etc. In my system this hidden page is called "AlmHornCtrl". I also have a page "AlmHornSelect" that allows adjustment of the sound files used during runtime (use either VBA or StringInput). Ric Walker, Automation & Electronics, Inc. , Casper, WY

 Здравствуйте всем. Может и глупый вопрос, но все же. Знатоки, подскажите пожалуйста. В проекте RSView32 работаю с удаленным OPC Kepware. При добавлении нового тега, в окне OPC Address Browser вижу следующее: server doesn't support browsing namespace Если же в адресе тега прописываю путь, то значения тегов удаленного OPC Kepware читаются. ИЗ Matrikon OPC Explorer Kepware вижу.

 [url=http://literature.rockwellautomation.com/idc/groups/literature/documents/qs/ftvp-qs002_-en-e.pdf]FactoryTalk View Point Quick Start Guide[/url] [img:63e2dcc0ee]http://i62.tinypic.com/2ai08q8.jpg[/img:63e2dcc0ee]

 У кого есть доступ к Knowledgebase не могли бы выложить содержание статьи: 29298 - How to play a sound file triggered by an Alarm

 Добрый день. У вас есть два пути решения проблемы. 1. Если в системе есть модули сети ModBus то пожалуйста связывайте панель таким образом. 2. Если по сети Ethernet то вам нужно создать мэпинг в программе контроллера как для связи с Микролоджик. А панель настроить как связь с Микролоджик. Оба варианта связи пробовали с CompactLogix. Если проект в панели большой, то ужасно будет тормозить, это тоже учтите.



Предыдущие результаты


Ещё результаты



Предыдущие результаты

Разделы


Предыдущие результаты



Предыдущие результаты


 nasirov-vg (Насыров Виктор)

 navigator (Шептала Вячеслав Владимирович)

 naygmus (Проскурин Николай)

 Neogar (Neogar)

 neoguy (Sergei O. Udalov)

 never35 (Gena)

 NGA (Александр)

 ng_1 (Наиль)

 NickelGov (RNick)

 NikName (Evgeniy)


Предыдущие результаты


Ещё результаты




Выберите страницу:   [ << Предыдущая страница ] 1 2


  
RA & VDT GmbH


Облако тэгов
ControlLogix MVI56-MCM Allen-Bradley Logix Windows FactoryTalk PanelView VersaView ControlTower GuardLogix Compact Software Studio Designer 100-E 100-D SMC-50 Energy Saver 1756-RMS-SC Spectrum Encompass Level Ethernet Redundancy Stratix

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.131 секунды