Предыдущие результаты
[quote:69d2bb1879="Vladimir_Ch"]можно, on-line редактирование есть.[/quote:69d2bb1879]
Онлайн редактирование нашел, но можно редактировать только в Tasks, а в Add-on Instructions не разрешает, желательно конечно как раз именно их и редактировать.
|
В качестве демо-версии можете использовать обычную рабочую версию, которая в течение определенного времени (т.н. grace period) имеет три врЕменные рабочие лицензии сроком на 7 дней:
[quote:ca200b4ba1][b:ca200b4ba1]What happens if the activation server is unavailable[/b:ca200b4ba1]
If the FactoryTalk Activation server is unavailable or [b:ca200b4ba1]unable to provide FactoryTalk ViewPoint licenses[/b:ca200b4ba1], the FactoryTalk ViewPoint Server will provide [b:ca200b4ba1]three temporary licenses[/b:ca200b4ba1] to connecting web browsers, for up to [b:ca200b4ba1]seven days[/b:ca200b4ba1].
To resume normal operations, before the s[b:ca200b4ba1]even-day grace period[/b:ca200b4ba1] expires, ensure that the activation server can provide the necessary licenses.
After the grace period expires, as soon as you restart the FactoryTalk ViewPoint Server, no web browsers will be able to view the published web application.[/quote:ca200b4ba1]
Где взять? У нас. Напишите в ближайший наш офис или на office@vdt-automation.de, мы дадим Вам ссылку, чтобы скачать этот пакет или пришлём диск.
|
Спасибо, это похоже то что нужно. Я как то сразу не обратил на этот софт внимания, думал что это тот же Active Display System только в новой обертке. Интересно было бы поюзать его. У него есть какая нибудь демо-версия?
|
Задача примерно такая:
Допустим есть два-три (не важно) автоматизированных объекта, т.е. контроллер - RSLinx - АРМ, здесь все понятно. Но допустим какие-то данные в динамике хотят просто видеть еще куча народа (мастер, начальник, диспетчер завода и т.д.). Настраиваем RSLinx OPC Server, разрабатываем на основе OPC DA своего клиента и все бы замечательно если бы OPC DA гарантировала соединение с удаленным OPC Server, и тут наступают проблемы: настройки DCOM, Брандмауэр, разные сборки винды и т.д. :o Т.е. как пишут разработчики стандарта OPC DA не предназначена для больших сетей, да еще если компьютера в разных доменах, соединение может произойти а может и нет.
Если использовать RSView32 Active Display System, во первых это лицензии, ну во вторых те же самые настройки DCOM.
Можно попробовать RSView WebServer, но с ним не сталкивался (есть у него какая нибудь ограниченная пробная версия?), и динамическое отображение объектов наверное на нем не построишь, надо каждый раз клиенту в ручную обновлять страницу.
Вот и напрашивается после всех злоключений использование стандарта OPC XML Servera, но похоже у Rockwella пока с этим ни как :cry:.
|
Если кому-то пригодится,вот что ответили в поддержке:
[list:f362b0d717]
Problem
Testing a display with a FactoryTalk Alarm and Events Alarm Summary object results in the following error in the Summary:
Insufficient Resources exist on <shortcut name> to support Alarm and Events functionality.
Environment
Application is trying to subscribe to Analog (ALMA) or Digital (ALMD) alarm
Controller running out of memory.
Ethernet module peaked at a very high CPU usage when you launch the Ethernet module Web browser.
Large number of Subscribers when you open one of the Analog (ALMA) or Digital (ALMD) instruction Properties Status tab.
Insufficient disk space.
Cause
Creating multiple backups of an Application with RSLinx Enterprise enabled for Alarm and Events support.
Solution
Open FactoryTalk Administration Console expand the Application.
Delete the RSLinx Enterprise server or right click on RSLinx Enterprise --> select Properties--> Uncheck Enable alarm and events support for older applications.
Note: Each RSLinx Enterprise server with Alarm and Events enabled will consume 100k of Controller memory for buffering.
49886 - SE 5.0 Alarm and Events Error: "Unable to subscribe to alarms from the controller plc insufficient memory to create subscription"
Access Level: TechConnect
Date Created: 03/04/2008 09:59 AM
Last Updated: 02/19/2011 10:45 AM
Neither a new SE project ( distributed or stand alone ), or an existing project ( that may have been working ) works with the Factory Talk Alarm and Events Summary, even though the PLC is triggering alarms successfully. We see the error: " Unable to subscribe to alarms from the controller plc insufficient memory to create subscription ."
This error is indicating that there is a memory issue in the Logix processor that is servicing the alarms and that the HMI server is unable to re-register with the alarm server.
Please check that there are sufficient resources in the Logix processor to service the HMI server.
This can also indicate an issue with licensing the dedicated project's HMI server activation is either being used by another HMI server running in parallel, or it ( example, RSVSERV.XXX ) does not exist on the PC. Check to see that we have enough activations free to attach to the current project and restart.
[/list:u:f362b0d717]
Всё касается вопросов связанных с ресурсами контроллера и "Alarm and Events".
|
ML1500 может работать в ModBus RTU через Сh1.
Вот пара полезных документов:
[url=http://vdt-automation.de/docs/ml1500_modbus.pdf]“Quick Start” Modbus Channel Configuration for Micrologix 1100/1200/1500 [/url]
[url=http://vdt-automation.de/docs/90000653_B.xls]Digi Protocol Briding Calculator[/url]
|
Использовать FTView для внесения изменений в проект RSView не получится. Для изменения проекта RSVIew32 понадобится пакет RSView32 Works.
Пакет RSView32 давно устарел, он выпускется более 15 лет. Почему бы Вам не заставить разработчиков конвертировать данный проект в FTView SE и не иметь в дальнейшем никаких проблем с его обслуживанием имеющимися средствами FTView Studio?
|
Я понимаю что MicroLogix 1500 поддерживает протоколы DF1 и DH-485, а modbus непонятно
1. MicroLogix 1500 LRP Series C может ли быть в сети modbus RTU Master?
2. Можно ли с помощью данного контроллера считывать с полевых устройств информацию по протоколу modbus RTU?
3. Какое решение посоветовали бы спецы в данной ситуации
|
Есть проект на операторскую станцию на компьютере, выполненный в RSView32. У меня стоит задача принятия на обслуживание системы. На текущий момент есть FactoryTalk View Studio ME и SE 5.00.00 CRP 9. Можно ли с помощью этих пакетов вносить изменения в проект, созданный в RSView32, в случае необходимости?
И еще вопрос, как выглядит проект RSView32? В том смысле, что, проект, созданный в FTView Studio, перед загрузкой в панель компилируется в исполняемый файл и этот файл уже можно только просматривать, поменять его нет никакой возможности. Как с этим обстоит дело в RSView32? Просто возникает необходимость принять от разработчиков этот проект, а с RSView32 дела не имел, не хочу чтобы подсунули аналог рантайм-файла в FTView Studio, я же потом его только просматривать смогу.
|
Произошла неустранимая основная ошибка контроллера (major fault). В
этом случае контроллер:
1. вначале покажет горящий красным индикатор
2. сбросит сам себя
3. сотрет проект из памяти
4. заставит индикатор мигать красным
5. произведет устранимую основную ошибку контроллера
6. сгенерирует код ошибки в проекте RSLogix 5000.
Для более точного ответа надо знать горел индикатор постоянно или мигал, а так все подробно написано в документе: 1769-UM011D-EN-P, CompactLogix System User Manual или 1769-UM011D-RU в приложении В-3 Таблица В.2
|
Предыдущие результаты
Ещё результаты |
|
| |
|