Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты



Предыдущие результаты

 Русская Winda XP со всеми сервис паками, они еще постоянно обновляются службой обновления, встроенной в винду. ошибка следующая: AppName: rs500.exe AppVer: 6.0.0.20 ModName: ntdll.dll ModVer: 5.1.2600.2180 Offset: 000111de плюс информация генегинуется дополнительная следующая (знаки тегов стер): ?xml version="1.0" encoding="UTF-16"? DATABASE EXE NAME="Rs500.exe" FILTER="GRABMI_FILTER_PRIVACY" MATCHING_FILE NAME="gkc1.dll" SIZE="1814528" CHECKSUM="0x141C3AD9" BIN_FILE_VERSION="0.4.0.48" BIN_PRODUCT_VERSION="0.4.0.48" PRODUCT_VERSION="4.48" FILE_DESCRIPTION="dll" COMPANY_NAME="Rockwell Automation Allen-Bradley" PRODUCT_NAME="A-B Compiler" FILE_VERSION="4.48" ORIGINAL_FILENAME="gkc1.dll" INTERNAL_NAME="gkc1" LEGAL_COPYRIGHT="Copyright © 1997-2000" VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x2" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="0.4.0.48" UPTO_BIN_PRODUCT_VERSION="0.4.0.48" LINK_DATE="12 11 2002 16:39:43" UPTO_LINK_DATE="12 11 2002 16:39:43" VER_LANGUAGE="Независимо от языка [0x0]" MATCHING_FILE NAME="RS0AUT32.dll" SIZE="122880" CHECKSUM="0x9124387C" BIN_FILE_VERSION="4.7.3.0" BIN_PRODUCT_VERSION="4.7.3.0" PRODUCT_VERSION="4.7.3.0" FILE_DESCRIPTION="RSI Software Activation" COMPANY_NAME="Rockwell Software Inc" PRODUCT_NAME="RSI-Activation" FILE_VERSION="4, 7, 3, 0" ORIGINAL_FILENAME="" INTERNAL_NAME="EVRSI" LEGAL_COPYRIGHT="Copyright © 1991-1999 Rockwell Software Inc. All rights reserved." VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x1" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="4.7.3.0" UPTO_BIN_PRODUCT_VERSION="4.7.3.0" LINK_DATE="02 02 2000 17:11:43" UPTO_LINK_DATE="02 02 2000 17:11:43" VER_LANGUAGE="Английский (США) [0x409]" MATCHING_FILE NAME="Rs500.exe" SIZE="7950336" CHECKSUM="0x9EDD3C3E" BIN_FILE_VERSION="6.0.0.20" BIN_PRODUCT_VERSION="6.0.0.20" PRODUCT_VERSION="6, 0, 0, 20" FILE_DESCRIPTION="RSLogix 500 Development Environment" COMPANY_NAME="Rockwell Software, Inc." PRODUCT_NAME="RSLogix 500" FILE_VERSION="6, 0, 0, 20" ORIGINAL_FILENAME="Rs500.exe" INTERNAL_NAME="RSLogix 500 Language Resource DLL" LEGAL_COPYRIGHT="Copyright © 1995-2003" VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x1" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="6.0.0.20" UPTO_BIN_PRODUCT_VERSION="6.0.0.20" LINK_DATE="02 13 2003 22:15:22" UPTO_LINK_DATE="02 13 2003 22:15:22" VER_LANGUAGE="Английский (США) [0x409]" MATCHING_FILE NAME="RSLGX500.dll" SIZE="2154496" CHECKSUM="0x341173EA" BIN_FILE_VERSION="6.0.0.20" BIN_PRODUCT_VERSION="6.0.0.20" PRODUCT_VERSION="6, 0, 0, 20" FILE_DESCRIPTION="Language resource file for RSLogix 500" COMPANY_NAME="Rockwell Software, Inc." PRODUCT_NAME="RSLogix 500" FILE_VERSION="6, 0, 0, 20" ORIGINAL_FILENAME="RSLGX500.DLL" INTERNAL_NAME="RSLogix 500 Language Resource DLL" LEGAL_COPYRIGHT="Copyright © 1995-2003" VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x4" VERFILETYPE="0x1" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="6.0.0.20" UPTO_BIN_PRODUCT_VERSION="6.0.0.20" LINK_DATE="02 13 2003 22:03:37" UPTO_LINK_DATE="02 13 2003 22:03:37" VER_LANGUAGE="Английский (США) [0x409]" MATCHING_FILE NAME="RSLGX_CT.dll" SIZE="651264" CHECKSUM="0x551477FE" BIN_FILE_VERSION="1.3.3.9" BIN_PRODUCT_VERSION="1.3.3.9" PRODUCT_VERSION="1, 3, 3, 9" FILE_DESCRIPTION="Logics Group Documentation Database API" COMPANY_NAME="Rockwell Software Inc." PRODUCT_NAME="Rockwell Software Inc. : Logics Database API" FILE_VERSION="1, 3, 3, 9" ORIGINAL_FILENAME="RSLGX_CT.DLL" INTERNAL_NAME="RSLGX_CT" LEGAL_COPYRIGHT="Copyright © 1996-2000" VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x4" VERFILETYPE="0x2" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="1.3.3.9" UPTO_BIN_PRODUCT_VERSION="1.3.3.9" LINK_DATE="07 18 2001 20:49:35" UPTO_LINK_DATE="07 18 2001 20:49:35" VER_LANGUAGE="Английский (США) [0x409]" MATCHING_FILE NAME="RSLGX_DB.DLL" SIZE="133120" CHECKSUM="0x7FA786D3" BIN_FILE_VERSION="1.0.0.1" BIN_PRODUCT_VERSION="1.0.0.1" PRODUCT_VERSION="5.30" FILE_DESCRIPTION="6200 Database Interface" COMPANY_NAME="Rockwell Software Inc." PRODUCT_NAME="Rockwell Software Logics Products" FILE_VERSION="5.30" ORIGINAL_FILENAME="RSLGX_DB.DLL" INTERNAL_NAME="RSLGX_DB" LEGAL_COPYRIGHT="Copyright © Rockwell Software, Inc. 1997" VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x2" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x5001E" UPTO_BIN_FILE_VERSION="1.0.0.1" UPTO_BIN_PRODUCT_VERSION="1.0.0.1" LINK_DATE="02 27 1997 00:52:24" UPTO_LINK_DATE="02 27 1997 00:52:24" VER_LANGUAGE="Английский (США) [0x409]" MATCHING_FILE NAME="rslogixmessages.dll" SIZE="45056" CHECKSUM="0x1E4F6B36" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" LINK_DATE="05 23 2001 20:12:27" UPTO_LINK_DATE="05 23 2001 20:12:27" MATCHING_FILE NAME="RSwl032.dll" SIZE="843776" CHECKSUM="0x9134BAF2" BIN_FILE_VERSION="5.0.0.36" BIN_PRODUCT_VERSION="5.0.0.36" PRODUCT_VERSION="5, 0, 0, 36" FILE_DESCRIPTION="RSI Software Activation" COMPANY_NAME="Rockwell Software Inc" PRODUCT_NAME="RSI-Activation" FILE_VERSION="5, 0, 0, 36" INTERNAL_NAME="EVRSI" LEGAL_COPYRIGHT="Copyright © 1991-1999 Rockwell Software Inc. All rights reserved." VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x1" MODULE_TYPE="WIN32" PE_CHECKSUM="0x0" LINKER_VERSION="0x0" UPTO_BIN_FILE_VERSION="5.0.0.36" UPTO_BIN_PRODUCT_VERSION="5.0.0.36" LINK_DATE="02 13 2003 20:03:55" UPTO_LINK_DATE="02 13 2003 20:03:55" VER_LANGUAGE="Английский (США) [0x409]" EXE EXE NAME="ntdll.dll" FILTER="GRABMI_FILTER_THISFILEONLY" MATCHING_FILE NAME="ntdll.dll" SIZE="712192" CHECKSUM="0x97E61B6C" BIN_FILE_VERSION="5.1.2600.2180" BIN_PRODUCT_VERSION="5.1.2600.2180" PRODUCT_VERSION="5.1.2600.2180" FILE_DESCRIPTION="Системная библиотека NT" COMPANY_NAME="Корпорация Майкрософт" PRODUCT_NAME="Операционная система Microsoft® Windows®" FILE_VERSION="5.1.2600.2180 (xpsp_sp2_rtm.040803-2158)" ORIGINAL_FILENAME="ntdll.dll" INTERNAL_NAME="ntdll.dll" LEGAL_COPYRIGHT="© Корпорация Майкрософт. Все права защищены." VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x2" MODULE_TYPE="WIN32" PE_CHECKSUM="0xBBF84" LINKER_VERSION="0x50001" UPTO_BIN_FILE_VERSION="5.1.2600.2180" UPTO_BIN_PRODUCT_VERSION="5.1.2600.2180" LINK_DATE="08 17 2004 23:04:04" UPTO_LINK_DATE="08 17 2004 23:04:04" VER_LANGUAGE="Русский [0x419]" EXE EXE NAME="kernel32.dll" FILTER="GRABMI_FILTER_THISFILEONLY" MATCHING_FILE NAME="kernel32.dll" SIZE="990208" CHECKSUM="0x2AFBEEE5" BIN_FILE_VERSION="5.1.2600.2945" BIN_PRODUCT_VERSION="5.1.2600.2945" PRODUCT_VERSION="5.1.2600.2945" FILE_DESCRIPTION="Библиотека клиента Windows NT BASE API" COMPANY_NAME="Корпорация Майкрософт" PRODUCT_NAME="Операционная система Microsoft® Windows®" FILE_VERSION="5.1.2600.2945 (xpsp_sp2_gdr.060704-2349)" ORIGINAL_FILENAME="kernel32" INTERNAL_NAME="kernel32" LEGAL_COPYRIGHT="© Корпорация Майкрософт. Все права защищены." VERFILEDATEHI="0x0" VERFILEDATELO="0x0" VERFILEOS="0x40004" VERFILETYPE="0x2" MODULE_TYPE="WIN32" PE_CHECKSUM="0xFFFD4" LINKER_VERSION="0x50001" UPTO_BIN_FILE_VERSION="5.1.2600.2945" UPTO_BIN_PRODUCT_VERSION="5.1.2600.2945" LINK_DATE="07 05 2006 10:56:32" UPTO_LINK_DATE="07 05 2006 10:56:32" VER_LANGUAGE="Русский [0x419]" EXE DATABASE

 Перед установкой можно попытаться проделать следующее: - в каталоге "Documents and Settings\All Users" создать папку "Documents" - запустить редактор реестра - ПУСК -> СТАРТ -> regedit - открыть HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders - изменить значение ключа "Common Documents" %ALLUSERSPROFILE%\Документы -> %ALLUSERSPROFILE%\Documents - закрыть редактор регистра - перезагрузить компьютер= В принципе, ничего сложного нет, может прокатит. С уважением, Vitaliy D. Burtsev

 [quote:9972d86f0b] Я через процедуры писать не пробовал. Это вы имеете в виду stored procedures? Не могли бы вы скинуть пару простеньких примеров, что бы хоть понять смысл всех этих вещей? Плз, на мыло :) И еще, заметил, что при записи в БД значения дискретного тэга, вместо 1 пишеться -1. Почему?[/quote:9972d86f0b] Очень зря. Через процедуры намного более гибко писать, хотя я только пробовал... :) И естественно это stored procedures. :) Скинуть .. подумаю... Пишутся значение 0/-1 согласно стандарту, не помню какому, но так принято. И вот чтоб такого не было работайте через процедуры, обработку ставьте или еще чего-ть. :D Ответ на цены по RSSQL, чем обна версия от другой отличается? Standard Version <-> Professional Version

 Проблемы нет никакой. Сохраните программу из контроллера на карточке, вставьте карточку в компьютер, она распознается, как диск. Следайте имедж с этого диска и пошлите коллеге мэйлом. Он запишет имедж карточки на свою такую же карточку и вставит в контроллер. Потом нужно загрузить программу с карточки, и если контроллер идентичен, всё будет работать. Вот, почитайте: [quote:48dd3b71ba][b:48dd3b71ba]G153127944: What happens to the application program in a L3x CompactLogix controller when it is powered down and up[/b:48dd3b71ba] When a CompactLogix controller is powered down, that is the power supply is powered down, the power supply sends a signal to the controller that power is going away. When the controllers gets this it will then save the program to battery back ram. When this is done the saved image is marked as valid. Then when the controller is powered back up it checks if anything is loaded in battery backed ram. If there is and it is marked as valid it is loaded in to memory. Then the battery back ram image is marked invalid. The marking of the image as invalid, after loading it, prevents the case of being able to load the wrong image into the controller, if for example, a new user program was loaded into the controller. Events that can cause the controller image to not be saved: 1. The CompactLogix power supply seeing an overvoltage condition. The power supply at this point does not go thru a normal shut down. 2. Unlocking the locking tab on any module between the controller and power supply. 3. Dead battery. 4. Disconnecting the battery after powering down. The image will be saved but lost. In the first 2 cases no image will be saved to battery backed ram. When the controller is powered back up the image saved in battery back ran is marked invalid and will not be loaded. So the controller will power up and appear to have lost its program. In case 3 the controller will save the image to battery back ram. Then the image will be retained for about 30 to 60 seconds. There are capacitors on the controller that will hold up the battery backed ram for 30 to 60 seconds. After the 30 to 60 seconds the controller will powerup and no program will be loaded. Important facts to know: 1. On a power down, the controller memory is saved to battery backed ram whether or not CompactFlash is installed. 2. [b:48dd3b71ba]If CompactFlash is installed and set to load "always", CompactFlash will win over battery backed ram.[/b:48dd3b71ba] 3. [b:48dd3b71ba]If the CompactFlash is installed and set to load "on corrupt", memory will be loaded from battery backed ram unless battery backed ram is corrupt.[/b:48dd3b71ba] 4. Disconnecting the battery after power is removed for 30 to 60 seconds will clear battery backed ram. 5. On power up once the program is restored from battery backed ram , the battery backed ram is marked invalid so that the image will not be re-loaded without a new power down save.[/quote:48dd3b71ba] Вот ещё небезинтересно почитать: [quote:48dd3b71ba][b:48dd3b71ba]G149027134 - Using a 1784-CF64 Card with Logix Controllers to Load Applications and Firmware[/b:48dd3b71ba] Summary of Technote Information: Starting at V12 the 1784-CF64 card would also store the firmware required for the application/project stored on the CompactFlash card. A common question is when will the firmware be updated and how should I configure the card for this to happen. A common request from customers is that they want to use the 1784-CF card to: 1. Reload the application/project to the controller if memory is lost. 2. Update the controllers firmware and load the application/project to the controller if it must be replaced. 3. Do not restore the application/project after a power cycle. The next question is how do I setup the Non-volatile storage feature to do all of these. Should the Load Image be selected as: 1. On Power Up 2. On Corrupt Memory Before we discuss this we should explain the process the controller goes thru. The controller determines what the restore options are. If the controller determines that a restore of the user program is called for it checks that the FW rev is correct. If it is not the controller will update the firmware and then reset itself. The controller will then check again what the restore options are. If the controller determines a restore of the user program is called for it checks that the firmware rev is correct. (This time it is.). Then we restore the user program. So for the above request you would want to select Load Image On Corrupt Memory. L6X controller at V13 (this applies to all controllers that use CompactFlash). Downloaded a program to it and created 2 CF cards. One set to load on powerup (1) and one set to load on corrupt memory (2). 1. Took another controller and loaded FW 15.4. No program loaded, no battery. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 2. Took another controller and loaded FW 12.XX. No program loaded, no battery. Took card 2 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 3. Took another controller and loaded FW 15.4 with the V15 version program loaded, battery. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 4. Took another controller and loaded FW 15.4 with the V15 version program loaded, battery. Took card 2 and inserted it into the controller. The controller stayed at V15 with the V15 program loaded. Nothing was loaded because the memory of the controller was not corrupt. 5. Took another controller loaded with factory default firmware. Took card 1 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. 6. Took another controller loaded with factory default firmware. Took card 2 and inserted it into the controller. The controller was flashed to V13 and the program was loaded. [/quote:48dd3b71ba]

 [quote:51e81962e0]Сколько стоит последняя версия продукта, на сколько тегов?[/quote:51e81962e0] Standard Version на 150 тэгов стоит 1463,00 Euro Standard Version на 300 тэгов стоит 2729,00 Euro Standard Version на 1500 тэгов стоит 4674,00 Euro Standard Version на 5000 тэгов стоит 6036,00 Euro Professional Version на 150 тэгов стоит 2752,00 Euro Professional Version на 300 тэгов стоит 5073,00 Euro Professional Version на 1500 тэгов стоит 8568,00 Euro Professional Version на 5000 тэгов стоит 9637,00 Euro Professional Version на 32000 тэгов стоит 12559,00 Euro Professional Version на 70000 тэгов стоит 15476,00 Euro

 Здравствуйте. Получили на фирму инсталляционный диск RSLogix 500, и, на том же диске, в дистрибутиве - RSView32. Но в главном меню диска, в пункте "Try out other Rockwell software products" RSView32 обозначена как demonstration version . Можно ли использовать, при наличии ключей активации от наших ранний версий, эту инсталляцию как полноценный SCADA пакет или она всё таки является урезанной демо версией пром.образца ?

 Всем добрый день! Возникла следующая проблема: на TrendX (дополнительном) не отображаются архивные данние, записанные в формате dBaseIV(Narrow), точнее отображаются, но с какими-то невероятными округлениями до цилых. Если пишу данные в SQL Server, все работает нормально! RSView32 version 6.4 Заранее благодарен!

 Здравствуйте. Подскажите, пожалуйста, что делать с такой проблемой: при загрузке проекта в RSView, когда прошло уже около 50% загрузки, выдается сообщение Connect to Watcom SQL, userID: tagdb, password ******. И далее, что бы ни делал, результат один - Database conversion failed: unable to connect to database server: unable to start database engine. Жму ОК, загрузка прерывается. Делал следующее: - Administrative Tools -> ODBC -> удалял Watcom SQL; - удалял каталог САСНЕ, файл *.сас; - настраивал Administrative Tools -> Services -> Network DDE и Network DDE DSDM -> в автоматический режим; - вводил пароль MMIPass; - создавал новый проект - но НИЧЕГО! Что можно сделать еще? Заранее благодарен.

 Очень часто нам задают вопросы о том, работают ли продукты Rockwell Software в русском Windows XP SP2. Работают. Здесь рассказывается, как именно. [b:12d3da6b5a]1.[/b:12d3da6b5a] Проверьте, располагаете ли Вы последней самой свежей версией Вашего программного продукта. Не забывайте регистрировать приобретённый программный продукт сразу же после его получения. Для регистрации обращайтесь, пожалуйста, к нам. Последние версии программных продуктов Rockwell Software: http://www.rockwellsoftware.com/corporate/revs/ От Вас потребуется фамилия лица, на которое зарегистирирован продукт (латинскими буквами, в том написании, в котором она была указана в регистрационной карточке) и Serial Number продукта (напечатан на коробке и введён при инсталляции). [b:12d3da6b5a]2.[/b:12d3da6b5a] Если приобретённый Вами программный продукт последней версии, пропустите этот пункт. Если нет - Вы можете скачать update прямо с сайта Rockwell Software, указав свои регистрационные данные: http://support.rockwellautomation.com/WebUpdates/ Если по какой-то причине Вы испытываете трудности со скачиванием актуальной версии программного продукта - обратитесь в любой из наших офисов, Вам с удовольствием помогут. Выполните update, корректно деинсталлировав старую версию и инсталлировав новую. [b:12d3da6b5a]3. [/b:12d3da6b5a]Итак, пограммный продукт имеет новейшую версию. Убедитесь пожалуйста,в том. что данная версия поддержана в Windows XP: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/42682/kw/compatibility%20matrix/r_id/115100 [b:12d3da6b5a]4.[/b:12d3da6b5a] Поддерживается? Тогда разберёмся с русским Windows. Вы уже знаете о том, что Вы должны быть администратором на этом РС? Проверьте это. [b:12d3da6b5a]5.[/b:12d3da6b5a] Загляните в папку C:\Documents and Settings. Проблема как раз в том, что папка "Администратор" называется русскими буквами. а именно путь вида "C:\Documents and Settings\Администратор" указан в системных переменных среды TEMP и TMP по умолчанию. [b:12d3da6b5a]6.[/b:12d3da6b5a] Создайте папки TEMP и TMP где-нибудь в таком месте, куда не ведёт путь с русскими буквами, - например, в C:\: C:\TEMP C:\TMP. [b:12d3da6b5a]7. [/b:12d3da6b5a] Откройте вкладку "Дополнительно" в "Панель Управления" -> "Система" и нажмите на кнопку "Переменные среды": [img:12d3da6b5a]http://vdt-automation.com.ua/files/a8.jpg[/img:12d3da6b5a] Измените пути по умолчанию, указав только что созданные папки. [img:12d3da6b5a]http://vdt-automation.com.ua/files/a9.jpg[/img:12d3da6b5a] [b:12d3da6b5a]8. [/b:12d3da6b5a] Нужно отключить FireWall, который встроен в Windows. Для Rockwell Software под SP2 и SP3 есть Windows Firewall Configuration Utility: http://rockwellautomation.custhelp.com/app/answers/detail/a_id/30498/kw/firewall/r_id/115100 [color=darkblue:12d3da6b5a] [u:12d3da6b5a][b:12d3da6b5a]Добавлена информация от уважаемого Dvoeglazov[/b:12d3da6b5a][/u:12d3da6b5a]:[/color:12d3da6b5a] Имя пользователя должно быть латинскими буквами, иначе не сохранить и не создать нового проекта в RSLogix5K. [b:12d3da6b5a]9. [/b:12d3da6b5a]Если Вы проделали всё, что тут написано и всё равно испытываете трудности, то скорее всего дело в Windows. ---------------------------------------------------- [color=darkblue:12d3da6b5a] [u:12d3da6b5a][b:12d3da6b5a]Добавлена информация от уважаемого dv_[/b:12d3da6b5a][/u:12d3da6b5a]:[/color:12d3da6b5a] [b:12d3da6b5a]10. [/b:12d3da6b5a]Измените переменные окружения в Windows: Было: [b:12d3da6b5a]C:\Documents and Settings\All Users\Документы[/b:12d3da6b5a] Нужно: [b:12d3da6b5a]C:\Documents and Settings\All Users\Documents[/b:12d3da6b5a] [b:12d3da6b5a]10. [/b:12d3da6b5a]Измените также настройки в реестре для Default User: Windows Registry Editor Version 5.00 [code:1:12d3da6b5a] [HKEY_USERS\.DEFAULT\Control Panel\International] "iCountry"="1" "iCurrDigits"="2" "iCurrency"="0" "iDate"="0" "iDigits"="2" "iLZero"="1" "iMeasure"="1" "iNegCurr"="0" "iTime"="0" "iTLZero"="0" "Locale"="00000409" "s1159"="AM" "s2359"="PM" "sCountry"="United States" "sCurrency"="$" "sDate"="/" "sDecimal"="." "sLanguage"="ENU" "sList"="," "sLongDate"="dddd, MMMM dd, yyyy" "sShortDate"="M/d/yyyy" "sThousand"="," "sTime"=":" "sTimeFormat"="h:mm:ss" "iTimePrefix"="0" "sMonDecimalSep"="." "sMonThousandSep"=" ," "iNegNumber"="1" "sNativeDigits"="0123456789" "NumShape"="1" "iCalendarType"="1" "iFirstDayOfWeek"="0" "iFirstWeekOfYear"="0" "sGrouping"="3;0" "sMonGrouping"="3;0" "sPositiveSign"="" "sNegativeSign"="-" [HKEY_USERS\.DEFAULT\Control Panel\International\Geo] "Nation"="241"[/code:1:12d3da6b5a] Возможно, этот код можно минимизировать, но это реально работающий код. После создания каталога [b:12d3da6b5a]C:\Documents and Settings\All Users\Documents[/b:12d3da6b5a]: [code:1:12d3da6b5a]Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders] "Common Documents"="C:\\Documents and Settings\\All Users\\Documents" [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders] "Common Documents"=hex(2):43,00,3a,00,5c,00,44,00,6f,00,63,00,75,00,6d,00,65,\ 00,6e,00,74,00,73,00,20,00,61,00,6e,00,64,00,20,00,53,00,65,00,74,00,74,00,\ 69,00,6e,00,67,00,73,00,5c,00,41,00,6c,00,6c,00,20,00,55,00,73,00,65,00,72,\ 00,73,00,5c,00,44,00,6f,00,63,00,75,00,6d,00,65,00,6e,00,74,00,73,00,00,00[/code:1:12d3da6b5a] [color=darkblue:12d3da6b5a]И ещё, о [b:12d3da6b5a].bat-файле[/b:12d3da6b5a] для ленивых:[/color:12d3da6b5a] Исходные данные: ОС: Windows Server 2003 R2, Standart edition, SP2 FT View Studio 5.00.00(cpr 9) build number: 55 Содержимое файлов: [b:12d3da6b5a]файл "setup.bat":[/b:12d3da6b5a] [code:1:12d3da6b5a]#-----начало setup.bat mkdir c:\Temp mkdir "%ALLUSERSPROFILE%\Documents "setup RSView SE 4.0.reg" @echo. @echo Please reboot your computer!!! @echo. @pause. #-----конец setup.bat[/code:1:12d3da6b5a] [b:12d3da6b5a]файл "setup RSView SE 4.0.reg":[/b:12d3da6b5a] [code:1:12d3da6b5a]#-----начало setup RSView SE 4.0.reg Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\FontSubstitutes] "Arial,0"="Arial,204" "Courier New,0"="Courier New,204" "Times New Roman,0"="Times New Roman,204" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SYSTEM\ControlSet002\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders] "Common Documents"=hex(2):25,00,41,00,4c,00,4c,00,55,00,53,00,45,00,52,00,53,\ 00,50,00,52,00,4f,00,46,00,49,00,4c,00,45,00,25,00,5c,00,44,00,6f,00,63,00,\ 75,00,6d,00,65,00,6e,00,74,00,73,00,00,00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders] "Common Documents"="C:\\Documents and Settings\\All Users\\Documents" [HKEY_CURRENT_USER\Environment] "TEMP"="c:\\Temp" "TMP"="C:\\Temp" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment] "TEMP"="C:\\TEMP" "TMP"="C:\\TEMP" #-----конец setup RSView SE 4.0.reg[/code:1:12d3da6b5a] Оба файла складываются в одну директорию и запускается [b:12d3da6b5a]setup.bat[/b:12d3da6b5a]



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
RSLogix ControlLogix sound FTView Control Logix MVI56-104S 1734-AENTR Altivar Add-on Instruction MVI46MCM Ethernet PLC-5 SLC-500 1757-SRM Firmware ComactLogixL32E 1756-L75 1756-RM2 Controlnet cable Promass Client Memory 1769-L32E execution minutes seconds Windows Build 00000d5c Unspecified terminate geehrter automatisch keine globalen Fehler

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.172 секунды