Вход на форум 
В начало e-Mail

Форум

Ресурсы Rockwell

Product Directory

Essential Components

Literature Library

Knowledge Base

Electronic News&Magazines

Блог

Encompass Program

Product Certification

  


Предыдущие результаты



Предыдущие результаты

 RSView32 Web Server

 Утечка памяти в RSViewSE

 Где взять Programming Manual RSView32

 Знакомство со SCANPORT

 Прогр. перевода фокуса в RSVIEW32 с одного объекта на другой

 Проблема при загрузке проекта RSView

 Отключение регистрации отдельных команд в Activity Log Setup

 Настройка RSLinx

 Не могу сконнектиться с АВ SLC500

 Проблема с активацией RSLogix



Предыдущие результаты


Ещё результаты

 Ну да, там же написано: "overload thermal protection". Читайте в оригинале, не читайте переводы. [quote:46d330a57e][b:46d330a57e]140M[/b:46d330a57e]-C, D and [b:46d330a57e]F [/b:46d330a57e]Frames: The 140M-C, D and F frame Motor Circuit Protectors have one UL/CSA Listing – as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page 2-20 for the specific ratings of each Motor Circuit Protector. The 140M-C, D and F Frame Motor Circuit Protectors are also UL/CSA Listed, together with a Bulletin 100C contactor and Bulletin 193 overload relay, as part of our Bulletin 103T and 107T Self-Protected IEC Combination Starters. [b:46d330a57e]These starters are then able to provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices[/b:46d330a57e].[/quote:46d330a57e]

 Двигатель 4кВт, примерно 8А 40M-F8E-C10 - Мотор-автомат 6.3-10А 193-ED1DP - Тепловое реле для 100-K, 3.2-16А 100-K12KF10 - Миниконтакторы 100-K, 12А Биметаллические теплухи ставятся в номинал. Автоматы, которые я использую последние лет 10, выбираются х1,5 - х2 в зависимости от условий. Мотор-автоматы дороже, использую редко, опыта мало. Электронные реле перегрузки ещё не использовал, но по докам, выходит, что они, как и биметаллические, тоже моделируют тепловой режим обмоток двигателя, при этом не зависят от тем-ры окр.среды. По идее, если судить по докам, мотор-автомат выбирается по номиналу мощности. Так-же, читая документацию на 40M-... , до конца не уверен, что правильно понял: данные автоматы обеспечивают функции теплового реле/нет? В русской доке: [quote:5f0d4d1f57]􀁹 Защита от короткого замыкания — магнитный расцепитель для стандартных токов отключения (установлено на 13 x Ie) 􀁹 [b:5f0d4d1f57]Защита от перегрузок — класс расцепления 10[/b:5f0d4d1f57] 􀁹 Компенсация температуры окружающей среды 􀁹 Защита от обрыва фазы 􀁹 Сертификация ATEX для типов C и D[/quote:5f0d4d1f57] На сайте Rockwell: [quote:5f0d4d1f57]Our Bulletin 140M Motor Protection Circuit Breakers can provide a disconnecting means for motor branch circuit, branch-circuit and short-circuit magnetic protection, [b:5f0d4d1f57]overload thermal protection[/b:5f0d4d1f57], and manual switching. These devices are rated from 0.1...630 A.[/quote:5f0d4d1f57]

 Может быть, эти сообраэжения помогут понять причину: [quote:fcf93e2f17]FAQ #1: what causes a RED battery LED on Softlogix5800 It will help to start with a little background. Under the hood, SoftLogix uses the same software that RSLogix 5000 does to maintain changes made by another workstation. A heartbeat thread in RSLogix 5000 periodically asks the controller if any changes have been logged to the change log. If so, it reads those changes and applies them to the current image. Likewise, in SoftLogix, there is a separate process, the SL5KServer, which has the same thread. The engine communications with its server via IPC and the server communicates to the engine using normal communication protocols via RSLinx. Following download, the SL5KServer opens the image sent to the engine during download and attempts to go online. Similarly, following a power cycle (or pull/redrop), the server opens an ACD, downloads it to the engine, and automatically goes online as part of a normal download. Either way, once the controller has an image to run, the SL5KServer should be online. Every 10 seconds, a thread in the engine asks the server if it is still online. If it is not, then the engine turns the battery LED ON (RED) and sends a command to the server to ask it to try to go online. If the battery LED was not already ON, it also logs a battery fault. If communications are just busy, the LED may go RED and then when the comm thread has more time, it may eventually turn green again. This thread checks every 10 seconds even if persistent storage save is disabled, since a save will still occur at powerdown. Every time interval, the thread referenced above in the engine will also ask the SL5KServer to perform a save. Following this, it should be clear that anything that would cause RSLogix 5000 to go offline will also cause the SL5KServer to go offline (and hence turn the battery LED RED). A few possibilities: Comm thread in engine not responding for 32 seconds. Any RSLinx communication problem (including a crash). Loss of communications with the engine. Loss of correlation. In addition to these possibilities, the following cases will also cause a RED LED: Fatal exception in SL5KServer (including RSLogix 5000 support DLLs). Any serious error that occurs in the save of the archive: hard disk errors, insufficient disk space, etc.[/quote:fcf93e2f17]

 Здравствуйте все! На компьютере, где развёрнут SoftLogix установлено: 1) Windows 7 Prof SP1 64 bit Рус. 2) RSLinx 3.51 Запущен драйвер VirtualBackPlane 3) SoftLogix V20.01 4) DEP settings set it to 'Turn on DEP for essential Windows programs and services only' При первоначальной загрузке программы в SoftLogix загорается красным Battery Fault, что говорит об ошибке "Persistent Storage Fault". Эта ошибка не даёт выгружать программу из SoftLogix и не позваляет стартовать с сохранённой программой. Как с этим побороться, есть свежие идеи? Заранее благодарен, Борис Сандлер

 Вопрос: Допустим, я ставлю 140M-F8E-C10 на 100-K12KF10. 140M-F8E-C10 обеспечивает: branch-circuit and short-circuit magnetic protection [b:1b97fb5868]overload thermal protection[/b:1b97fb5868] manual switching Ставить/нет дополнительно на пускатель 100-K12KF10 электронное тепловое реле 193-ED1DP?

 Всё правильно, Logix CPU Security Tool не работает с контроллерами версии v21. [quote:4c361752a5]For version 20 or later of the application, if the security commands are unavailable, you need to install FactoryTalk Services Platform.[/quote:4c361752a5] См. публикацию [url=http://literature.rockwellautomation.com/idc/groups/literature/documents/pm/1756-pm016_-en-p.pdf]1756-PM016H-EN-P Logix5000 Controllers Security - March 2015 [/url], со стр. 13

 все в норме комуникация тоже работает. В Logix CPU Security Tool вибираю контролер 1756-L71 и когда нажимаю OK видает эту ошибку. Logix CPU Security Version 3.0 Studio 5000 Logix Desinger Version 21.0 standart edition RS Linx clasic lite version 3.60.00 CPR 9 SR6

 [quote:3c0c9bf275="orshu"]У нас RSView32 версии 7.30[/quote:3c0c9bf275] Так сделайте update на 7.60.

 [quote:0e449d9730]в конце выдает ошибку [/quote:0e449d9730] Извините, но отсюда экрана Вашего компьютера не видно. Давайте подробно: - кто, когда, и в конце чего выдает такую ошибку - версия Firmware контроллера - версия RSLogix - есть ли связь RSLinx (и RSLogix) с контроллером? - есть ли связь Logix CPU Security Tool с контроллером?

 Начни [url=http://www.rockwellautomation.com/rockwellsoftware/products/factorytalk-view-se.page?#ordering-information]отсюда[/url]. Коротко и приблизительно:[list:b940423cd4]FactoryTalk View Site Edition Station <-> RSView32 Runtime FactoryTalk View Site Edition Station + FactoryTalk View Studio <-> RSView32 Works FactoryTalk View Site Edition Server + FactoryTalk View Site Edition Client(s) <-> нет аналога[/list:u:b940423cd4]



Предыдущие результаты


Ещё результаты



Предыдущие результаты

Разделы


Предыдущие результаты



Предыдущие результаты


 odessa740 (Yuriy)

 oevgen78 (Evgeny Ogurtsov)

 ogorodec (YanAmosov)

 oin7 (Alexsey)

 oknesyl (lysenko)

 Oksana (Oksana)

 oksya (oksana)

 oksyalogo (oksanalogo)

 Olas (Виктор)

 olegators68 (Олег )


Предыдущие результаты


Ещё результаты




Выберите страницу:   [ << Предыдущая страница ] 1 2 3 4


  
RA & VDT GmbH


Облако тэгов
sound FTView Control Logix MVI56-104S 1734-AENTR Altivar Add-on Instruction MVI46MCM Ethernet PLC-5 SLC-500 1757-SRM Firmware ComactLogixL32E 1756-L75 1756-RM2 Controlnet cable Promass Client Memory 1769-L32E execution minutes seconds Windows Build 00000d5c Unspecified terminate geehrter automatisch keine globalen Fehlermeldungen Default Stan

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.138 секунды