 [quote:fd03827a5e="oldDad"] [quote:fd03827a5e="dv_"][b:fd03827a5e]FactoryTalk View SE[/b:fd03827a5e] самое оно, но нужен отдельно сервер и нужное количество клиентов + среда разработки.[/quote:fd03827a5e] Отдельные серверы и клиенты совершенно необязательно иметь. В продукте FactoryTalk View Site Edition Station содержится и сервер, и клиент "в одном флаконе": [quote:fd03827a5e]FactoryTalk View Site Edition Station allows stand-alone (non-distributed) applications to run on a single computer.[/quote:fd03827a5e][/quote:fd03827a5e] Моя фраза про отдельные сервер и клиент была основана на: [quote:fd03827a5e="trofim"]Интересно будет ли работать такая схема RSView клиент-сервер на одной машине,несколько машин связанные в сеть через ХАБ далее пара клиентов(диспечер,контора)[/quote:fd03827a5e] Импортировать проект [b:fd03827a5e]RSView32 [/b:fd03827a5e]можно, но дорабатывать придеться (для [b:fd03827a5e]Local [/b:fd03827a5e]меньше, для [b:fd03827a5e]Network [/b:fd03827a5e]больше): [URL=http://piccy.info/][img:fd03827a5e]http://i.piccy.info/i4/4c/4e/73e7270684a5bcee483774e355b4.jpeg[/img:fd03827a5e][/URL]

 [quote:7b172261e9="trofim"]попробовал демо версию RSView32/v7/10гдето в инете скачал. Работает прекрасно создал несколько объектов и дисплей диспечера ,связь с серверами локально,передача данных,все работает,но говорят на такие продукты лицензии нет,устарел.[/quote:7b172261e9] Продукт RSView32 выпускается примерно 14 лет, и уже устарел. Он ещё продаётся, но для новых систем не рекомендуется, т.к. не оптимизирован для работы с современными контроллерами и коммуникациями. [quote:7b172261e9="trofim"]Нашел в инете RSViewSE, блин с установкой одни проблеммы[/quote:7b172261e9] Немудрено. Мало ли, что Вы там и где нашли. RSViewSE - это серьёзный продукт, к нему идёт несколько томов документации. Ставить его нужно точно по документации, и лучше - после курса обучения. Иначе у вас ничего хорошего может и не получится. И уж во всяком случае не нужно качать что попало откуда попало. Гораздо проще, надёжнее и эффективнее обратиться к нам, Вам покажут и научат, а демо-версия денег не стоит. [quote:7b172261e9="dv_"][b:7b172261e9]FactoryTalk View SE[/b:7b172261e9] самое оно, но нужен отдельно сервер и нужное количество клиентов + среда разработки. См. http://www.rockwellautomation.com/rockwellsoftware/performance/view/orderinginfo.html[/quote:7b172261e9] Отдельные серверы и клиенты совершенно необязательно иметь. В продукте FactoryTalk View Site Edition Station содержится и сервер, и клиент "в одном флаконе": [quote:7b172261e9]FactoryTalk View Site Edition Station allows stand-alone (non-distributed) applications to run on a single computer.[/quote:7b172261e9]

 На приводимой Вами страничке имеется новейшая версия 16.56Std "1756-Lxx Standard Redundancy Bundle with 1757-SRM" и с ней документ Release Notes 1756-RN628J-EN-E: В документе на стр. 2 сказано: [quote:ebf4481fbe]IMPORTANT Only the modules specified in the table below can be used in the standard redundancy system and this firmware revision. Modules that are not listed in the table are not compatible with the standard redundancy system and are not supported by this redundancy firmware revision.[/quote:ebf4481fbe] и приведены необходимые версии firmware для Вашего оборудования. Вам необходимо загрузить с сайта этот 16.56Std "1756-Lxx Standard Redundancy Bundle with 1757-SRM" и прошить перечисленные в таблице модули указанными версиями прошивки. Я порекомендовал бы также тщательно выполнить все процедуры и проверить все параметры конфигурации, приведенные в документе 1756-UM523F-EN-P.

 Здравствуйте. Решил попробовать собрать следующую конфигурацию: Comp 1: FT Directory (FTSP); Comp2: Design-time client (FTSP, RSLinx Enterprise, Factory Talk View Studio); Comp 3: Data server (FTSP, [b:37277a5abe]RSLinx Enterprise or RSLinx Classic[/b:37277a5abe], RS Emulate); Comp 4: HMI Server (FTSP, IIS, Factory Talk View SE Server); Comp 5: Run-time Client (FTSP, Factory Talk View SE Client). Данная конфигурация приведена в Factory Talk View Installation Assistant. Собственно вопрос, а в чем будет разница, если поставить RSLinx Enterprise вместо RSLinx Classic, те суть – разница между RSLinx Enterprise и RSLinx Classic? Документация имеется, но в силу того что данный продукт нов для меня, то тяжеловато. Заранее спасибо.

 Процедура заключается в подаче напряжения через токоограничивающий резистор в течении определенного времени. The Issue: In the past, Rockwell Automation has received numerous information requests from customers pertaining to drives that have not had power applied to them for a long period of time. The major concern regarding the Drives would be the affect of time on the Aluminum Electrolytic Capacitors. Bus Capacitors that have not had power applied to them for a period of 4 years or longer should undergo a Bus Capacitor re-forming process. What is Re-forming? Re-forming is a technical term used with capacitors that have been unpowered for a long time. To understand the re-forming process, we must first understand the forming process. To create any capacitor, three items are needed: 1.) An Anode (positive end), 2.) A Cathode (negative end), and 3.) A dielectric inserted between the two foils. An Aluminum Electrolytic capacitor follows this basic formula using aluminum foil both as the anode and the cathode, with an aluminum oxide formed on the foil as a dielectric and liquid electrolyte as a conductor. Capacitance is directly related to the surface area of the anode foil; the more surface area, the greater the capacitance. To increase the surface area of the anode foil, manufacturers dip the foil into an acid bath. This bath etches grooves into the foil, thus increasing the surface area (see figure 1). After this process, a non-conductive, insulating aluminum oxide, Al2O3, is grown on the surface of the aluminum anode and cathode foil, including the etched grooves. A thin paper layer is added between the foils to prevent them from rubbing against each other and to hold/absorb the conductive electrolyte that is used to reduce the distance between the anode and cathode. The aluminum oxide formed on the foil is the insulator between the positive and negative plates, but the aluminum oxide formed on the foil is a brittle material. When this oxide cracks, a leakage current will flow between the anode and cathode. This does not cause the capacitor to fail. In fact, the leakage current causes localized heating, which creates more oxide, thus sealing off the leak. Unfortunately, after a prolonged period of time, four to five years, with a lack of voltage applied to an aluminum electrolytic capacitor, the oxide will start to breakdown and the leakage current will be very high. If voltage is applied to the capacitors at this point, the high leakage current (ripple current) could cause enough heating to vaporize the electrolyte in the capacitor causing the part to vent or potentially explode. To prevent this from happening, the capacitors need to be re-formed. Re-forming is the process of re-growing the oxide in the grooves of the aluminum foil. The simple way to re-form an aluminum electrolytic capacitor is to apply a controlled DC voltage. The DC voltage will create the proper amount of leakage current that will form new oxide. How do you Re-form? The best way to re-form the bus capacitors would be to individually apply the capacitor.s rated DC voltage through a current limited resistor (~ 300 Ohms minimum) for period of 1 hour. However, this would require disassembling the entire drive. Some Rockwell Automation Drives are equipped for common bus applications, these drives have a plus and minus DC voltage input on the power terminal block connector. With the Rockwell Automation Drives that have this configuration, a high voltage (~ 800V) DC power supply used in series with the current limiting resistor would be connected to the terminal block to apply the rated DC voltage for an hour. Disconnect the Drives control boards and I/O boards prior to applying the DC voltage. Otherwise, the external power supply will turn on the Drive and in the process draw too much current and overload the supply. With the Rockwell Automation Drives that do not have this terminal block configuration, the other option is to apply the input line voltage to the Drive, the current limited resistor should still be used in series with the input power. Then allow the drive to power-up, thus applying bus voltage across the capacitors and re-forming them. Allow the drive to sit in this state for at least an hour prior to operating the drive. Experiment and Results: Several bus capacitors that had not had any applied voltage in seven years were tested in an attempt to verify the re-forming process. The capacitors had full rated voltage applied to them using an external DC power supply through a 1k Ohm resistor. A current meter was also used to watch the leakage current in the capacitor. Once the DC voltage was applied the leakage current started high and dropped rapidly. After a few minutes, the leakage current leveled off and the capacitors were successfully re-formed.

 [quote:9576582d07="Fed_85"]Добрый день! Не подскажете, можно ли скачать проект визуализации с панели оператора (Allan-Bradley)? Если да, то по каким средствам можно это сделать. И желательно по-подробней эту процедуру описать... Заранее благодарен![/quote:9576582d07] Для [b:9576582d07]PanelView Standard [/b:9576582d07](2711-*) - используется [b:9576582d07]PanelBuilder 32[/b:9576582d07], расширение исполняемого файла *.PVA. Для [b:9576582d07]PanelView Plus [/b:9576582d07](2711P-*) - используется [b:9576582d07]Factory Talk View Machine Edition[/b:9576582d07], расширение исполняемого файла *.MER, преобразовать файл в набор исходный файлов можно только для версии 5.00 (CPR 9). Если терминал старый будут проблемы - между версиями 2 и 3 произошла смена процессора. Из [b:9576582d07]PanelView Plus [/b:9576582d07] приложение можно записать на [b:9576582d07]CF[/b:9576582d07] (с версии 3 и старше) или на [b:9576582d07]PCMCIA[/b:9576582d07] (для младших версий) - на карточке создать файл [b:9576582d07]Autorun.bat[/b:9576582d07] со следующей строкой [b:9576582d07]copy \"storage card"\"rockwell software"\rsviewme\runtime\*.mer \"storage card 2"\[/b:9576582d07]

 [quote:4efe2b9fa3="oldDad"]Не очень понятно, какой именно вопрос Вы хотели бы задать авторам FT View Machine Edition. Не могли бы Вы его сформулировать конкретно?[/quote:4efe2b9fa3] ну это скорей описание баги, ибо в логе все таки инфа для программиста, обработанная исключением. попробую описать: [u:4efe2b9fa3]Имеются[/u:4efe2b9fa3] два компа: Comp1 - уже установлена FT View Machine Edition V5.00.00 и на нем написан проект под панель AB PanelView Plus1000 Comp2 - чистый комп, на который требуется перенести все ПО для работы [u:4efe2b9fa3]Действия:[/u:4efe2b9fa3] 1. устанавливаем FT View Machine Edition V5.00.00 на Comp2, регистрируем запускаем. 2. Создаем проект с именем [b:4efe2b9fa3]blablabla[/b:4efe2b9fa3] на Comp2 3. Удаляем проект с именем [b:4efe2b9fa3]blablabla[/b:4efe2b9fa3] через [b:4efe2b9fa3]Application Manager --> Delete application[/b:4efe2b9fa3] на Comp2 4. Делаем экспорт проекта с Comp1 через [b:4efe2b9fa3]Application Manager --> Backup application[/b:4efe2b9fa3]. Проект на другом компе называется тоже [b:4efe2b9fa3]blablabla[/b:4efe2b9fa3] 5. Делаем импорт проекта на Comp 2 через [b:4efe2b9fa3]Application Manager --> Restore application[/b:4efe2b9fa3] [u:4efe2b9fa3]Результат:[/u:4efe2b9fa3] В процессе импорта проекта на Comp2 (Действие №5) всплывает сообщение, в котором говорится, что проект с таким именем уже существует в лог добавляются 2 записи: The distanation specified in a call to CopyDestroy(), RenameDestroy() or RestoreDestroy() already exists. Error: HRESULT = "0x80042054" Location = ".\DestroyServer.cpp, Line: 5249" Успешно импортировать проект можно только указав иное имя, например [b:4efe2b9fa3]blablabla1[/b:4efe2b9fa3] [u:4efe2b9fa3]Примечания:[/u:4efe2b9fa3] В реестре программы по поиску строки "blablabla" нет каких либо записей, относящихся к проекту.

 [quote:4faf46aa9c="dv_"]Примите мои соболезнования и вперед в реестр...[/quote:4faf46aa9c] уже давно там)) как бы соболезнования не принял реестр :lol: кстати при создании в лог пишет: The distanation specified in a call to CopyDestroy(), RenameDestroy() or RestoreDestroy() already exists. Error: HRESULT = "0x80042054" Location = ".\DestroyServer.cpp, Line: 5249" но думаю это к авторам проги вопрос)

 Да. Делал так как в мануале (Publication 1756-UM007A-EN-P - October 2000) на модуль написано. В Message Configuration указывал следующие параметры: Закладка Configuration Message Type: CIP Generic Service Code: 4c Class: 4 Instance: 16 Attribute: 0 Source Element: Local:2:C (модуль 1756-HSC) Source Lenght: 124 Destination: пусто Закладка Communication Path: путь к 1756-HSC галки возле Connected и Cash Connection поставил. Пробовал и в LADе напрямую в модуль писать.

 итак о решении данной проблемы) [b:da08909e1a]оргомнейшая[/b:da08909e1a] благодарность техподдержке ООО "ВДТ-Тольятти" исходные данные: ОС: Windows Server 2003 R2, Standart edition, SP2 FT View Studio 5.00.00(cpr 9) build number: 55 так как фалы прикреплять нельзя, то выкладываю их содержимое. может кому еще пригодится. файл "setup.bat": #-----начало setup.bat mkdir c:\Temp mkdir "%ALLUSERSPROFILE%\Documents "setup RSView SE 4.0.reg" @echo. @echo Please reboot your computer!!! @echo. @pause. #-----конец setup.bat файл "setup RSView SE 4.0.reg": #-----начало setup RSView SE 4.0.reg Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\FontSubstitutes] "Arial,0"="Arial,204" "Courier New,0"="Courier New,204" "Times New Roman,0"="Times New Roman,204" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SYSTEM\ControlSet002\Control\Nls\CodePage] "1250"="c_1251.nls" "1251"="c_1251.nls" "1252"="c_1251.nls" [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\User Shell Folders] "Common Documents"=hex(2):25,00,41,00,4c,00,4c,00,55,00,53,00,45,00,52,00,53,\ 00,50,00,52,00,4f,00,46,00,49,00,4c,00,45,00,25,00,5c,00,44,00,6f,00,63,00,\ 75,00,6d,00,65,00,6e,00,74,00,73,00,00,00 [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders] "Common Documents"="C:\\Documents and Settings\\All Users\\Documents" [HKEY_CURRENT_USER\Environment] "TEMP"="c:\\Temp" "TMP"="C:\\Temp" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment] "TEMP"="C:\\TEMP" "TMP"="C:\\TEMP" #-----конец setup RSView SE 4.0.reg оба файла складываются в одну директорию и запускается setup.bat



Предыдущие результаты


Ещё результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты



Предыдущие результаты




  
RA & VDT GmbH


Облако тэгов
version Rockwell ProSoft Modbus Automation ControlLogix MVI56-MCM Allen-Bradley Logix Windows FactoryTalk PanelView VersaView ControlTower GuardLogix Compact Software Studio Designer 100-E 100-D SMC-50 Energy Saver 1756-RMS-SC Spectrum Encompass Level Ethernet Redundancy Stratix

Яндекс цитирования

Smart Solutions VDT GmbH | Friedrich-List-Allee 38, D-41844 Wegberg-Wildenrath, Germany
Tel.: +49 2432 933 57 83 | e-Mail: office@vdt-solutions.de
Все товарные знаки и торговые марки являются собственностью их владельцев.
При использовании материалов сайта ссылка на данный сайт обязательна.
Открытие страницы: 0.167 секунды